圆柱形瓣膜用于新生儿及小儿童二尖瓣和三尖瓣置换
本研究报道了手工制作的圆柱形瓣膜用于房室瓣环小于15 mm的婴儿及小儿童二尖瓣或三尖瓣置换的初步经验。8例患者中位年龄6.9个月,植入均技术成功,无显著反流、狭窄或左室流出道梗阻;3例早期死亡与合并严重病变相关,2例需早期再干预,随访中2例改换16 mm机械瓣,2例存活良好。结论认为该技术可行,可允许体格生长并为后续植入合适尺寸机械瓣创造条件。
要点
- 圆柱形瓣膜可用于瓣环小于15 mm的婴幼儿房室瓣置换。
- 8例植入均技术成功,无显著反流、狭窄或左室流出道梗阻。
- 3例早期死亡均合并严重病变,2例需早期再干预。
核心结论
- 圆柱形瓣膜行房室瓣置换技术可行,无技术问题,可帮助脱离困难局面并允许体格生长和后续植入合适尺寸机械瓣。
研究设计与样本
- 单中心初步经验报告,共纳入8例需行房室瓣置换且瓣环小于15 mm的患者,中位年龄6.9个月(范围1天至38个月)。
- 圆柱形瓣膜为手工制作:将12 mm Contegra瓣膜置入14 mm Gore-Tex管状移植物内并在两端缝合。
主要发现
- 4例二尖瓣置换、4例三尖瓣置换,所有植入均技术成功,无显著反流、无狭窄、无左室流出道梗阻。
- 3例早期死亡死于低心排,均合并严重相关病变(严重新生儿Ebstein畸形、室间隔完整的肺动脉闭锁、Norwood一期后双心室转换)。
- 2例需早期再干预:1例因狭窄行球囊扩张,1例因瓣周漏再手术。
- 随访中2例分别在圆柱形瓣膜植入后9个月和20个月改换16 mm机械瓣。
- 其余2例在术后2年2个月时存活且状况良好。
临床怎么用
- 对于瓣环小于15 mm、缺乏合适尺寸人工瓣膜的婴幼儿房室瓣病变,可考虑手工圆柱形瓣膜作为过渡方案。
- 术后需警惕低心排死亡(尤其合并严重病变者)及瓣周漏、狭窄等需再干预的并发症。
- 该方案可为患儿体格生长后植入合适尺寸机械瓣争取时间。
局限性
- 本研究为单中心初步经验,样本量仅8例,结果需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Atrioventricular valve replacement in small children is associated with high morbidity and mortality. There are no prostheses available with a diameter ˂15 mm. This study reports our initial experience with a cylinder valve for mitral and tricuspid valve replacement in infants and small children. METHODS: Our cylinder valve was hand-made for patients requiring atrioventricuclar valve replacement with an annulus of <15 mm. A 12-mm Contegra valve was prepared and placed inside a 14-mm Gore-Tex tube graft and sutured on both extremities. RESULTS: Eight patients were included, with a median age of 6.9 months (range 1 day to 38 months). Four had mitral and 4 had tricuspid valve replacement. All implants were technically successful, with no significant regurgitation, no stenosis and no left ventricular outflow tract obstruction. There were 3 early deaths from low cardiac output, in patients with significant associated lesions (severe neonatal Ebstein's, pulmonary artery-intact ventricular septum, biventricular conversion from Norwood stage 1). Two patients required early reintervention: 1 for balloon dilatation for stenosis and 1 for reoperation for paravalvular leak. During follow-up, 2 patients had mitral valve replacement with a 16-mm mechanical valve at 9 and 20 months from the cylinder valve implantation. The remaining 2 patients are alive and well 2 years and 2 months after the procedure. CONCLUSIONS: Cylinder valve replacement of atrioventricular valves was feasible without any technical issues. It was successful in getting out of a difficult situation and allows for somatic growth and implantation of a reasonably-sized mechanical prosthesis on the annulus.
引用
- Myers PO, Dave H, Kretschmar O, et al. Cylinder mitral and tricuspid valve replacement in neonates and small children. Eur J Cardiothorac Surg. 2020. PMID: 32844202. doi:10.1093/ejcts/ezaa196
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。