文献速递主动脉外科

远端锚定区不良条件下的胸主动脉腔内修复术

Thoracic Endovascular Aortic Repair in the Setting of Compromised Distal Landing Zones.
PubMed 文献 · Ann Thorac Surg · 2020-07-06

BACKGROUND: The short-term and intermediate-term outcomes of two distinct approaches to thoracic endovascular aortic repair (TEVAR) for descending aortic aneurysms in patients with compromised distal landing zones are reported.…

要点

  • 中期随访1B型内漏35%、再干预15%、全因死亡25%。

核心结论

  • TEVAR是远端锚定区不良的胸腹主动脉瘤患者的可行替代方案。
  • 联合辅助技术可能限制该人群远端锚定区的进行性退化。

研究设计与样本

  • 远端锚定区不良定义为:腹腔干上2 cm内主动脉直径≥3.5 cm、附壁血栓≥50%、环形钙化≥25%,或腹腔干上10 cm内迂曲指数≥1.1。
  • 治疗分组:单纯TEVAR组(n=29);联合辅助组(n=20,内脏烟囱支架+远端支架延伸,或EndoAnchors n=6)。

主要发现

  • 中位临床随访2.2年,1B型内漏35%,最大主动脉直径年增长≥0.5 cm者9%,再干预15%,全因死亡25%。

临床怎么用

  • 对远端锚定区不良的降主动脉瘤患者,TEVAR可作为可行治疗选择。
  • 联合辅助技术(烟囱支架+远端延伸或EndoAnchors)可能延缓远端锚定区扩张。
  • 需密切随访内漏和锚定区直径变化,必要时再干预。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The short-term and intermediate-term outcomes of two distinct approaches to thoracic endovascular aortic repair (TEVAR) for descending aortic aneurysms in patients with compromised distal landing zones are reported. METHODS: Fifty-one patients (38 female, average age 72 ± 9 years) underwent 55 TEVARs (2008 to 2018) for aneurysmal disease. Inclusion criteria consisted of TEVAR in a compromised distal landing zone, defined as follows: diameter 3.5 cm or greater; cross-sectional thrombus 50% or greater; or 25% or greater circumferential mural calcification in the 2 cm supraceliac aorta; or tortuosity index of 1.1 or more over the 10 cm supraceliac aorta. Treatment cohorts were (1) TEVAR alone (n = 29), and (2) TEVAR with adjunct consisting of visceral snorkel graft with distal stent extension (n = 20) or EndoAnchors (Medtronic, Minneapolis, MN [n = 6]). RESULTS: Perioperative complication rate was 20%. Thirty-day mortality was 5% including one access-site related intraoperative death and one postoperative death from embolic mesenteric ischemia. Median clinical follow-up was 2.2 years. Intermediate-term outcomes include type 1B endoleaks, 35%; 0.5 cm or more per year maximal aortic diameter growth, 9%; reintervention, 15%; and all-cause mortality, 25%. The distal landing zone diameter increased by 0.3 cm per year in the TEVAR alone cohort; however, it decreased by 0.1 cm per year in the adjunct cohort ( P = .04). CONCLUSIONS: Thoracic endovascular aortic repair is a viable alternative for the treatment of thoracoabdominal aortic aneurysms in patients with compromised distal landing zones, although these patients may benefit significantly from the development of branched thoracoabdominal devices. In the interim, the use of TEVAR adjuncts may limit progressive degeneration of the distal landing zone in this patient population.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. DuBois BG, Houben IB, Khaja MS, et al. Thoracic Endovascular Aortic Repair in the Setting of Compromised Distal Landing Zones. Ann Thorac Surg. 2020. PMID: 32645338. doi:10.1016/j.athoracsur.2020.05.074

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。