文献速递主动脉外科

新型三区混合移植物:急性I型主动脉夹层的首例人体经验

New 3-zone hybrid graft: First-in-man experience in acute type I dissection.
PubMed 文献 · J Thorac Cardiovasc Surg · 2020-05-06

本研究报道6例危重急性I型主动脉夹层患者使用新型三区混合移植物(升主动脉涤纶段、主动脉弓裸支架、降主动脉覆膜支架)的中期结果。手术在深低温停循环和选择性顺行脑灌注下完成,手术死亡率为17%(1例),平均随访19±12个月,影像学显示无吻合口相关近端入口及远端真腔塌陷。结论认为该技术可实现快速可靠的修复至中胸段水平。

要点

  • 三区混合移植物可快速修复急性I型夹层至中胸段水平
  • 头臂血管开口裸支架置入未导致狭窄或阻塞
  • 手术死亡率17%,中期随访无吻合口相关近端入口

核心结论

  • 实现急性I型主动脉夹层快速可靠修复至中胸段水平的目标似乎可行。
  • 头臂血管开口裸支架置入不引起狭窄或阻塞。
  • 下一步计划开展多中心研究。

研究设计与样本

  • 单中心首例人体经验,2016年7月至2018年4月纳入6例I型急性主动脉夹层患者,平均年龄69岁,均在同情用药基础上植入三区混合移植物。
  • 手术在远端深低温停循环和选择性顺行脑灌注下完成。

主要发现

  • 手术死亡率为17%(n=1)。
  • 平均阻断时间和选择性顺行脑灌注时间分别为92分钟和34分钟,最后2例分别降至75/65分钟和23/24分钟。
  • 平均随访19±12个月,期间行1次远端血管内延伸术。
  • 影像学控制显示无吻合口相关近端入口,下游无真腔塌陷。

临床怎么用

  • 对于危重急性I型主动脉夹层患者,可考虑使用三区混合移植物在深低温停循环和选择性顺行脑灌注下实现快速近端修复并保留远端假腔隔绝优势。

局限性

  • 样本量小(6例),为单中心首例人体经验,需多中心研究进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Acute type I aortic dissection (AAD) represents a surgical emergency with time-dependent evolving complications. Frozen elephant trunk (FET) enables false lumen exclusion downstream but is still debated in AAD due to its greater dimension of surgery. To combine the benefits of fast proximal repair with the FET benefits, a 3-zone hybrid graft was developed consisting of an ascending polyester portion, an arch noncovered stent, and a descending stent graft. Mid-term results of this new technique are presented. METHODS: A total of 6 patients (age mean 69 years) with type I AAD in critical status (Penn classification B n = 5, BC n = 1) were operated between July 2016 and April 2018 using the 3-zone hybrid graft. The device was implanted on the basis of strict compassionate use. Operations were performed under distal hypothermic circulatory arrest and selective antegrade cerebral perfusion (SACP). RESULTS: Operative mortality was 17% (n = 1). Mean crossclamp and SACP time were 92 and 34 minutes, respectively, but came down in the last 2 cases to 75/65 crossclamp and 23/24 SACP minutes each. During follow up, mean 19 ± 12 months, one endovascular extension downstream was performed. Imaging control demonstrated no anastomotic-related proximal entry and no true lumen collapse downstream. CONCLUSIONS: The goal to achieve fast and reliable repair of complicated type I AAD down to midthoracic level seems to be achievable. Noncovered stenting of the head vessel's origin does not cause stenosis or obstruction. A multicenter studying of this concept is next.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Jakob H, Shehada SE, Dohle D, et al. New 3-zone hybrid graft: First-in-man experience in acute type I dissection. J Thorac Cardiovasc Surg. 2020. PMID: 32653283. doi:10.1016/j.jtcvs.2020.04.113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。