升主动脉替换术后及中期血流动力学变化
本研究通过颈动脉压力波形记录,评估升主动脉瘤患者的主动脉扩张性及脉搏波形,并分析人工血管替换升主动脉后的术后及中期血流动力学变化。结果显示升主动脉瘤与迟脉相关,替换为刚性人工血管后早期收缩期压力斜率变陡,但中期与对照组相当,且整体主动脉僵硬度未见恶化。
要点
- 升主动脉瘤患者表现为迟脉,早期收缩期压力曲线斜率较对照组更低。
- 刚性人工血管替换升主动脉后早期收缩期斜率变陡,中期与对照组相当。
- 术后及中期颈-股脉搏波速度未见明显变化,整体主动脉扩张性未恶化。
核心结论
- 本研究未证实刚性人工血管替换升主动脉会引起下游严重血流动力学改变,因未观察到整体主动脉扩张性恶化。
- 升主动脉瘤与迟脉相关。
研究设计与样本
- 研究纳入30例接受升主动脉瘤人工血管替换的患者和30例对照患者,采用经皮动脉张力计记录颈动脉水平中心血压波形。
- 测量时间点为术前1天、术后5至7天及术后16至20个月。
主要发现
- 升主动脉瘤组早期收缩期压力曲线斜率低于对照组(0.54 ± 0.18 mm Hg/ms vs 0.69 ± 0.26 mm Hg/ms;P = .011)。
- 颈-股脉搏波速度术前为9.0 ± 2.6 m/s,术后为9.0 ± 2.9 m/s,中期为9.3 ± 2.8 m/s,均无显著变化。
临床怎么用
- 升主动脉瘤患者出现迟脉时,应评估主动脉扩张性及脉搏波形。
- 升主动脉替换术后,刚性人工血管未导致整体主动脉僵硬度恶化,中期血流动力学可恢复至与对照组相当。
局限性
- 样本量较小(30例患者和30例对照),可能影响结果的普遍性。
- 仅通过颈动脉张力计记录中心血压波形,未直接测量主动脉扩张性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate aortic distensibility and pulse waveform patterns associated with the ascending aortic aneurysm, and to analyze the postoperative and mid-term hemodynamic changes induced by prosthetic replacement of the ascending aorta. METHODS: Central blood pressure waves were recorded at the carotid artery level by means of a validated transcutaneous arterial tonometer in 30 patients undergoing prosthetic replacement of ascending aortic aneurysm and in 30 control patients. Measurements were obtained the day before surgery and 5 to 7 days and 16 to 20 months after surgery. RESULTS: The ascending aortic aneurysm was associated with a less steep slope of early systolic phase of the pressure curve (pulsus tardus) compared with a control group (0.54 ± 0.18 mm Hg/ms vs 0.69 ± 0.26 mm Hg/ms; P = .011). Replacing the ascending aorta with a noncompliant vascular prosthesis steepened the pulse pressure slope during the early systolic phase in the postoperative period (0.77 ± .29 mm Hg/ms), providing values comparable with those of the control group in the mid-term (0.67 ± .20 mm Hg/ms). No change in aortic stiffness was found either postoperatively or in the mid-term after ascending aorta surgical replacement (carotid-femoral pulse wave velocity: preoperative, 9.0 ± 2.6 m/s; postoperative, 9.0 ± 2.9 m/s; mid-term postoperative, 9.3 ± 2.8 m/s). CONCLUSIONS: This study does not confirm the assumption that substitution of the viscoelastic ascending aorta with a rigid prosthesis can cause serious hemodynamic alterations downstream, because we did not observe a worsening of global aortic distensibility after insertion of a rigid prosthetic aorta. The ascending aortic aneurysm is associated with a pulsus tardus.
引用
- Salvi L, Alfonsi J, Grillo A, et al. Postoperative and mid-term hemodynamic changes after replacement of the ascending aorta. J Thorac Cardiovasc Surg. 2020. PMID: 32624310. doi:10.1016/j.jtcvs.2020.05.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。