本研究基于STS全国数据库2007至2017年243,142例孤立性主动脉瓣置换术成人患者,随机按4:1分为训练集与验证集,评估极端梯度提升(XGBoost)预测STS模型涵盖结局的表现。XGBoost校准良好,平均观察/预期比为0.985;对7个结局中5个的c指数较STS模型显著改善,2个结局相当。

要点

  • XGBoost在孤立性SAVR中校准优秀,平均O/E比0.985。
  • 7个结局中5个的c指数较STS模型显著提升。
  • 卒中与深部胸骨伤口感染两结局c指数与STS模型相当。

核心结论

  • XGBoost在孤立性SAVR中校准优秀,判别能力较现有STS模型有适度改善。

研究设计与样本

  • 回顾性队列研究,数据来自STS全国数据库2007至2017年孤立性SAVR成人患者243,142例。
  • 患者随机按4:1分为训练集与验证集,评估STS模型涵盖的结局。
  • 采用极端梯度提升(XGBoost)机器学习算法。
  • 校准用观察/预期比、校准-in-the-large和校准曲线斜率衡量,判别用c指数衡量。

主要发现

  • XGBoost校准优秀:平均观察/预期比0.985,校准-in-the-large为-0.017,校准曲线斜率0.944。
  • 再手术c指数63.7%(95%CI 62.7%–64.8%) vs 62.6%(95%CI 61.5%–63.7%),P=0.01。

临床怎么用

  • XGBoost可用于孤立性SAVR的结局预测,校准良好且部分结局判别优于STS模型。
  • 对手术死亡、延长通气、急性肾衰竭、再手术及死亡/主要并发症复合结局,XGBoost判别能力显著优于STS模型。
  • 对卒中与深部胸骨伤口感染,XGBoost与STS模型判别能力相当。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study evaluated the performance of a machine learning (ML) algorithm in predicting outcomes of surgical aortic valve replacement (SAVR). METHODS: Adult patients undergoing isolated SAVR in The Society of Thoracic Surgeons (STS) National Database between 2007 and 2017 (n = 243,142) were randomly split 4:1 into training and validation sets. Outcomes that were evaluated were those for which STS models exist. The ML algorithm extreme gradient boosting (XGBoost) was used. Model calibration was measured by the ratio of observed to expected risk, calibration-in-the-large, and slope of calibration curve, and model discrimination was measured by the c-index. RESULTS: XGBoost demonstrated excellent calibration, with an average observed-to-expected ratio of 0.985, calibration-in-the-large of -0.017, and slope of calibration curve of 0.944. The c-index of XGBoost was significantly improved compared with STS models for 5 of 7 outcomes: operative mortality (77.1% [95% confidence interval {CI}, 75.8% to 78.4%] vs 76.2% [95% CI, 75.0% to 77.6%]; P = .007), prolonged ventilation (73.9% [95% CI, 73.1% to 74.6%] vs 72.6% [95% CI, 71.9% to 73.4%]; P < .001], acute renal failure (77.6% [95% CI, 76.3% to 78.7%] vs 73.7% [95% CI, 72.2% to 75.0%]; P < .001), reoperation (63.7% [95% CI, 62.7% to 64.8%] vs 62.6% [95% CI, 61.5% to 63.7%]; P = .01), and the composite of mortality or major morbidity (70.3% [95% CI, 69.6% to 70.9%] vs 69.0% [95% CI, 68.3% to 69.7%]; P < .001). For 2 outcomes the c-index was comparable: stroke (68.4% [95% CI, 66.6% to 70.3%] vs 67.6% [95% CI, 65.7% to 69.5%]; P .08) and deep sternal wound infection (59.9% [95% CI, 53.6% to 66.2%] vs 64.1% [95% CI, 57.5% to 70.1%]; P = .82). CONCLUSIONS: The ML algorithm XGBoost demonstrated excellent calibration and modest improvements in discriminatory ability compared with existing STS models in this study of isolated SAVR.