二尖瓣成形环对左室血流动力学的影响:三维 cine 相位对比磁共振评估
研究采用三维 cine 相位对比磁共振成像,比较健康志愿者与二尖瓣修复术后患者的左室涡流模式、主动脉流出模式及血流能量损失(EL)。结果显示二尖瓣修复术后左室EL高于健康志愿者,完整成形环干扰主动脉流出模式,相对患者体型较小的成形环扰乱左室血流模式并导致高EL。
要点
- 二尖瓣修复术后左室血流能量损失高于健康志愿者。
- 完整成形环可干扰主动脉流出模式及EL分布。
- 相对体型较小的成形环扰乱左室血流并致高EL。
核心结论
- 二尖瓣修复尤其使用相对较小的成形环时,可诱导异常左室血流模式和EL升高,有望成为术后新的血流动力学评估方法。
主要发现
- 二尖瓣修复术后左室涡流模式与健康志愿者不同。
- 半硬质装置下前二尖瓣叶下方涡流在舒张早期呈双股状,柔性带下呈单股状并向心尖大幅移位。
- 二尖瓣修复术后患者LVEL为0.84 ± 0.42 mW,高于健康志愿者的0.47 ± 0.10 mW。
- 完整成形环干扰主动脉流出模式并伴EL分布改变。
- 相对患者体型较小的装置扰乱左室血流模式并导致高EL。
关键数值与推荐
- 索引成形环孔面积与跨二尖瓣平均压差无显著关系(r = -0.25, P = .414)。
- 索引成形环孔面积与LVEL呈负相关(r = -0.84, P < .001)。
临床怎么用
- 二尖瓣修复术后可考虑用三维cine相位对比磁共振评估左室血流模式和EL。
- 选择成形环尺寸时需关注相对患者体型大小对左室血流和EL的潜在影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: We assessed the influence of annuloplasty procedures in mitral repair on left ventricular (LV) vortex flow patterns and aortic outflow patterns, and flow energy loss (EL). METHODS: Twenty healthy volunteers and 14 patients who had undergone mitral valve repair were examined using 3-dimensional cine phase-contrast magnetic resonance imaging. A band group included 7 patients with semi-rigid and 2 with flexible partial bands. The ring group included 5 patients with semi-rigid complete rings. LV vortex flow patterns, aortic outflow patterns, EL, and aortic annulus changes during one cardiac cycle were evaluated. RESULTS: Mitral repair induced different vortex flow patterns compared with that of healthy volunteers. The vortex beneath the anterior mitral leaflet with semi-rigid devices was double-stranded in early diastole, and it was single-stranded with flexible bands with a large shift toward the apex during diastole. LVEL in patients who underwent mitral repair (0.84 ± 0.42 mW) was greater than that in healthy volunteers (0.47 ± 0.10 mW). Complete rings disturbed aortic outflow patterns, with EL distribution changes. Smaller devices relative to patient body size disturbed LV flow patterns and caused high EL. No significant relationship was found between indexed ring orifice area and transmitral mean pressure gradient (r = -0.25, P = .414), but a negative relationship exists between indexed ring orifice area and LVEL (r = -0.84, P < .001). CONCLUSIONS: Mitral repair, especially with relatively small annuloplasty rings, induced abnormal LV flow patterns and EL elevation, which have the potential to be a novel hemodynamic evaluation method after mitral repair.
引用
- Morichi H, Itatani K, Yamazaki S, et al. Influences of mitral annuloplasty on left ventricular flow dynamics assessed with 3-dimensional cine phase-contrast flow magnetic resonance imaging. J Thorac Cardiovasc Surg. 2020. PMID: 32690416. doi:10.1016/j.jtcvs.2020.04.127
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。