文献速递瓣膜外科主动脉外科

应用几何环环缩术修复单叶式主动脉瓣

Unicuspid Aortic Valve Repair Using Geometric Ring Annuloplasty.
PubMed 文献 · Ann Thorac Surg · 2020-06-30

该多中心研究纳入20例单叶式主动脉瓣患者,采用二叶式环缩环行瓣膜修复,并处理次要融合处交界切开。术后平均跨瓣压差从25.8 mmHg降至16.2 mmHg,主动脉瓣反流从2.9级降至0.1级(P < .001),无死亡或主要并发症。平均随访11个月,全部患者无症状且恢复日常活动。

要点

  • 几何环环缩术可有效缩小瓣环直径,增加瓣叶对合。
  • 次要融合交界切开及瓣环重塑使修复简单可重复。
  • 术后血流动力学及反流显著改善,短期随访结果良好。

核心结论

  • 主动脉环环缩术能有效缩小瓣环直径,使更多瓣叶参与中线对合,将单叶式主动脉瓣修复转为简单可重复的手术。

研究设计与样本

  • 多中心回顾性研究,9家机构共20例单叶式主动脉瓣患者接受瓣膜修复术。

主要发现

  • 平均年龄22.3 ± 12.3岁(范围13-58岁),12/20(60%)有症状,10/20(50%)需行动脉瘤切除。
  • 修复前平均收缩期跨瓣压差25.8 ± 12.9 mmHg,主动脉瓣反流2.9 ± 1.2级,瓣环直径24.7 ± 3.3 mm。
  • 修复后瓣环(环)尺寸20.5 ± 1.3 mm,平均压差降至16.2 ± 5.9 mmHg,反流降至0.1 ± 0.3级(P < .001)。
  • 平均随访11个月(范围1-22月),全部20例患者无症状且恢复全部活动,无死亡或主要并发症。

关键数值与推荐

  • 对次要融合行交界切开,并将具有圆形基底几何和两个180度交界下支柱的二叶式环缩环缝合于瓣环下,以均衡融合与非融合瓣叶的瓣环周长。
  • 对非融合瓣叶行折叠术,并线性关闭主要融合处的裂隙,直至瓣叶有效高度和长度分别大于8 mm且相等。

临床怎么用

  • 对于单叶式主动脉瓣,可采用二叶式环缩环行瓣环重塑,结合次要融合交界切开及瓣叶修复技术,以改善对合和血流动力学。

局限性

  • 样本量小(20例),随访时间短(平均11个月,范围1-22月),缺乏长期耐久性数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Unicuspid aortic valves (Sievers type 2 bicuspid) are characterized by major fusion and clefting of the right-left coronary commissure, and minor fusion of the right-noncoronary commissure. Repair has been difficult because of two fusions, variable relative sinus sizes, and peripheral leaflet deficiencies or tears after balloon valvuloplasty. METHODS: Twenty unicuspid aortic valves patients underwent valve repair in nine institutions. Right-left major fusion and right-noncoronary minor fusion occurred in 17 of 20 (85%). Commissurotomy was performed on the minor fusion, and a bicuspid annuloplasty ring with circular base geometry and two 180-degree subcommissural posts was sutured beneath the annulus, equalizing the annular circumferences of the fused and nonfused cusps. The nonfused leaflet was plicated, and the cleft in the major fusion was closed linearly until leaflet effective heights and lengths became greater than 8 mm and equal, respectively. RESULTS: Average age (mean ± SD) was 22.3 ± 12.3 years (range, 13 to 58), 12 of 20 (60%) were symptomatic, 10 of 20 (50%) required aortic aneurysm resection. Pre-repair hemodynamic data included mean systolic valve gradient 25.8 ± 12.9 mm Hg, aortic insufficiency grade 2.9 ± 1.2, and annular diameter 24.7 ± 3.3 mm. No mortality or major complications occurred. Post-repair annular (ring) size was 20.5 ± 1.3 mm, mean gradient fell to 16.2 ± 5.9 mm Hg, and aortic insufficiency grade decreased to 0.1 ± 0.3 (P < .001). At an average follow-up of 11 months (range, 1 to 22), all 20 patients were asymptomatic and had returned to full activity. CONCLUSIONS: Aortic ring annuloplasty reduced annular diameter effectively, recruiting more leaflet to midline coaptation. Minor fusion commissurotomy and annular remodeling to 180-degree commissures converted UAV repair to a simple and reproducible procedure.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Si MS, Conte JV, Romano JC, et al. Unicuspid Aortic Valve Repair Using Geometric Ring Annuloplasty. Ann Thorac Surg. 2020. PMID: 32619617. doi:10.1016/j.athoracsur.2020.04.147

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。