文献速递瓣膜外科

经颈动脉TAVR术后同侧脑缺血负担及相关因素

Cerebral Embolism After Transcarotid Transcatheter Aortic Valve Replacement: Factors Associated With Ipsilateral Ischemic Burden.
PubMed 文献 · Ann Thorac Surg · 2020-07-23

前瞻性研究纳入52例经颈动脉途径行TAVR的患者,术后行弥散加权磁共振成像(DW-MRI)评估双侧大脑半球缺血负担。同侧半球至少1个缺血病灶的患者比例高于对侧(84.6% vs 63.5%,P=.005),同侧病灶数亦更多(2 vs 1,P=.005)。使用较大鞘管/输送系统(≥18F vs ≤16F)与同侧缺血负担增加相关(P=.026)。

要点

  • 经颈动脉TAVR后同侧半球脑缺血病灶数目多于对侧
  • 较大鞘管/输送系统(≥18F)与同侧缺血负担增加相关
  • 术中无围手术期卒中事件,但亚临床脑缺血病灶常见

核心结论

  • 经颈动脉途径TAVR与同侧大脑半球脑缺血病灶数目增多相关。
  • 使用较大鞘管/输送系统(≥18F)与同侧缺血负担增加相关。

研究设计与样本

  • 前瞻性研究,纳入52例行经颈动脉TAVR并术后行DW-MRI检查的患者。
  • 所有DW-MRI由对临床数据设盲的放射科医师离线分析。

主要发现

  • 同侧与对侧半球至少1个脑缺血病灶的患者比例分别为84.6%和63.5%(P=.005)。
  • 同侧与对侧半球每患者缺血病灶数分别为2(四分位距1-5)和1(四分位距0-3)(P=.005)。
  • 每病灶体积及每患者平均病灶体积在两半球间无差异。
  • 较大鞘管/导管尺寸(≥18F vs ≤16F)与更高的同侧缺血负担相关(P=.026)。
  • 所有患者手术成功,1例发生需补片修补的颈动脉夹层,无围手术期卒中事件。

临床怎么用

  • 经颈动脉TAVR术后应关注同侧半球亚临床脑缺血,尤其使用≥18F鞘管/输送系统时。
  • 可考虑将DW-MRI用于评估经颈动脉TAVR的脑缺血负担。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Transcarotid transcatheter aortic valve replacement (TAVR) recipients may be exposed to a higher ipsilateral subclinical cerebral ischemic burden compared with the contralateral hemisphere. We sought (1) to compare the cerebral ischemic burden of the 2 hemispheres after transcarotid TAVR, as evaluated by diffusion weighted-magnetic resonance imaging (DW-MRI), and (2) to identify the factors associated with ipsilateral ischemic burden. METHODS: This prospective study included 52 patients undergoing transcarotid TAVR, followed by a DW-MRI examination. All DW-MRIs were analyzed offline by a radiologist blinded to the clinical data. RESULTS: TAVR was performed through the left (n = 50) or right (n = 2) carotid artery. Procedural success was achieved in all patients, carotid dissection requiring patch closure occurred in 1 patient, and there were no periprocedural stroke events. At least 1 cerebral ischemic lesion was identified in the ipsilateral and contralateral hemisphere in 84.6% and 63.5% of patients, respectively (P = .005), and the number of ischemic lesions per patient was higher in the ipsilateral vs the contralateral hemisphere (2 [interquartile range, 1-5] vs 1 [interquartile range, 0-3], P = .005). The lesion volume (per lesion) and the average lesion volume (per patient) did not differ between the 2 hemispheres. A larger sheath/catheter size (≥18F vs ≤16F) was associated with a higher ipsilateral ischemic burden (P = .026). CONCLUSIONS: Carotid artery access for TAVR was associated with a higher number of cerebral ischemic lesions in the ipsilateral (vs contralateral) cerebral hemisphere. The use of a larger sheath/delivery system (≥18F) was associated with an increased ipsilateral ischemic burden.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Faroux L, Junquera L, Mohammadi S, et al. Cerebral Embolism After Transcarotid Transcatheter Aortic Valve Replacement: Factors Associated With Ipsilateral Ischemic Burden. Ann Thorac Surg. 2020. PMID: 32710845. doi:10.1016/j.athoracsur.2020.05.139

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。