免缝合与快速部署瓣膜11年国际注册研究趋势
基于SURD-IR注册2007至2018年3682例患者,分析免缝合与快速部署主动脉瓣置换(SURD-AVR)的趋势与结局。11年间患者年龄和预估手术风险下降,孤立手术微创入路从49.4%升至85.5%。院内死亡率孤立与联合手术分别为1.6%和3.9%且无变化,围术期卒中、起搏器植入和主动脉瓣反流均显著下降。
要点
- SURD-AVR应用趋向年轻、低风险患者,微创入路显著增加。
- 孤立与联合SURD-AVR院内死亡率分别为1.6%和3.9%,11年无变化。
- 围术期卒中、术后起搏器植入和主动脉瓣反流均显著减少。
核心结论
- SURD-AVR在更年轻人群中应用增多且更常采用微创技术,临床结局显著改善。
研究设计与样本
- SURD-IR国际注册研究分析2007至2018年3682例患者,按手术日期分6组,孤立SURD-AVR 2472例,联合SURD-AVR 1086例。
主要发现
- 11年间患者年龄和预估手术风险下降,孤立SURD-AVR微创入路从49.4%增至85.5%。
- 孤立与联合手术院内死亡率分别为1.6%和3.9%,随时间无变化。
- 围术期卒中从4%降至0.5%,术后起搏器植入从12.8%降至5.9%,主动脉瓣反流从17.8%降至2.7%。
临床怎么用
- SURD-AVR可用于年轻低风险患者,微创入路应用增多,需关注起搏器植入和瓣周反流。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Current evidence on sutureless and rapid deployment aortic valve replacement (SURD-AVR) is limited and does not allow for the assessment of the clinical impact and the evolution of procedural and clinical outcomes of this new valve technology. The Sutureless and Rapid Deployment International Registry (SURD-IR) represents a unique opportunity to evaluate the current trends and outcomes of SURD-AVR interventions. METHODS: Data from 3682 patients enrolled between 2007 and 2018 were analysed. Patients were divided according to the date of surgery into 6 equal groups and by the type of intervention: isolated SURD-AVR (n = 2472) and combined SURD-AVR (n = 1086). RESULTS: Across the 11-year study period, significant changes occurred in patient characteristics including a decrease in age and in estimated surgical risk. Less invasive approaches for isolated SURD-AVR increased considerably from 49.4% to 85.5%. The overall in-hospital mortality rate was 1.6% and 3.9% in isolated and combined procedures, respectively, with no change over time. The rate of perioperative stroke decreased significantly (from 4% to 0.5%), as did the rates of postoperative pacemaker implantation (from 12.8% to 5.9%) and aortic regurgitation (from 17.8% to 2.7%). CONCLUSIONS: The present study provides a comprehensive analysis of the current trends and results of SURD-AVR interventions. The most notable changes over time were the increasing implantation of SURD valves in a younger population, with more frequent utilization of less invasive techniques. SURD-AVR demonstrated remarkable improvements in clinical outcomes with a significant reduction in the rates of stroke, pacemaker implantation and postoperative aortic regurgitation.
引用
- Berretta P, Arzt S, Fiore A, et al. Current trends of sutureless and rapid deployment valves: an 11-year experience from the Sutureless and Rapid Deployment International Registry. Eur J Cardiothorac Surg. 2020. PMID: 32356876. doi:10.1093/ejcts/ezaa144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。