文献速递瓣膜外科

二尖瓣修复游离缘连续缝合技术的中期随访结果

Continued follow-up of the free margin running suture technique for mitral repair.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

无手术死亡,随访期二尖瓣反流复发率低,瓣膜功能稳定,静息及运动负荷下舒张期性能表现良好。

要点

  • FMRS技术治疗复杂退行性二尖瓣病变中期瓣膜功能稳定,反流复发率低。
  • 随访期平均跨二尖瓣压差较出院时显著下降(4.8±1.5 vs 3.5±0.9 mmHg,P<0.001)。
  • 运动负荷超声显示静息与峰值运动平均跨瓣压差差异有统计学意义(3.2±0.7 vs 5.1±1.3 mmHg,P<0.001),未见显著二尖瓣反流。

核心结论

  • FMRS技术有效且可重复,中期瓣膜功能稳定,静息及运动下舒张期性能表现良好。

研究设计与样本

  • 所有患者出院时及随访时行静息超声心动图,其中17例行负荷超声心动图。

主要发现

  • 无手术死亡;86.1%经右迷你开胸完成FMRS,5.6%为机器人辅助,8.3%经胸骨正中切口。
  • 双叶病变占31.4%;出院时1例(0.9%)存在2+/4+残余二尖瓣反流,随访时1例(0.9%)存在2+/4+二尖瓣反流。
  • 出院时与随访时对合长度分别为1.3±0.2 cm与1.3±0.1 cm(P=0.13)。
  • 出院时与随访时平均跨二尖瓣压差分别为4.8±1.5 mmHg与3.5±0.9 mmHg(P<0.001)。
  • 亚组负荷超声显示静息与峰值运动平均跨二尖瓣压差分别为3.2±0.7 mmHg与5.1±1.3 mmHg(P<0.001),无显著二尖瓣反流出现,肺动脉收缩压升高临界显著(P=0.049)。

临床怎么用

  • FMRS可用于复杂退行性二尖瓣病变的修复,中期随访显示瓣膜功能稳定。
  • 术后随访可结合静息与负荷超声心动图评估瓣膜功能及舒张期性能。

局限性

  • 随访时间有限(平均2.5±2.5年),为中期结果。
  • 负荷超声心动图仅在17例亚组患者中完成。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The free margin running suture (FMRS) technique was recently proposed to treat complex degenerative mitral lesions. Limited follow-up data are available. We evaluated the midterm reliability of this technique and the associated mitral valve parameters using rest/stress echocardiography. METHODS: One-hundred-eight consecutive patients at 2 European centres were included. Prospective follow-up was performed (266.1 patient-years, average duration 2.5 ± 2.5 years). Echocardiographic scans at rest were obtained for all patients at hospital discharge and at follow-up. Stress echocardiography was also performed in 17 patients. RESULTS: There were no operative deaths. FMRS was performed through a right minithoracotomy in 86.1% of patients, with a robotic-assisted technique in 5.6% and through a sternotomy in 8.3%. Bileaflet disease was noted in 31.4%. One patient (0.9%) presented a 2+/4+ residual mitral regurgitation at discharge; lower-degree or no residual regurgitation was noted in the remaining patients. At the follow-up examination, 1 patient (0.9%) presented with a 2+/4+ mitral regurgitation. Coaptation length at discharge versus that at follow-up was 1.3 ± 0.2 vs 1.3 ± 0.1 cm (P = 0.13); the average transmitral gradient was 4.8 ± 1.5 vs 3.5 ± 0.9 mmHg (P < 0.001). In a subpopulation, follow-up echocardiography indicated that the average transmitral gradient at rest versus that at peak effort was 3.2 ± 0.7 vs 5.1 ± 1.3 mmHg (P < 0.001), with no appearance of significant mitral regurgitation and marginally significant increases in pulmonary artery systolic pressures (P = 0.049). CONCLUSIONS: Data indicate effectiveness and reproducibility of FMRS, with stability of valve function at midterm. FMRS was also associated with promising outcomes in diastolic performance both at rest and during exercise.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Agnino A, Graniero A, Roscitano C, et al. Continued follow-up of the free margin running suture technique for mitral repair. Eur J Cardiothorac Surg. 2020. PMID: 32380519. doi:10.1093/ejcts/ezaa122

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。