文献速递主动脉外科

升主动脉瘤≥5 cm与<5 cm患者壁应力分析比较

Wall stress analyses in patients with ≥5 cm versus <5 cm ascending thoracic aortic aneurysm.
PubMed 文献 · J Thorac Cardiovasc Surg · 2020-02-19

本研究用有限元分析比较升主动脉瘤(aTAA)≥5.0 cm(n=47)与<5.0 cm(n=53)患者的个体化瘤壁峰值应力,发现≥5.0 cm组峰值环向与纵向应力总体更大但组间差异未达统计学意义;≥5.0 cm组瘤径与峰值应力有一定相关性,而<5.0 cm组相关性差。

要点

  • ≥5.0 cm组峰值环向应力530±83 kPa,<5.0 cm组486±87 kPa(P=.07)。
  • ≥5.0 cm组瘤径与峰值环向应力相关系数0.41,<5.0 cm组仅0.23。
  • <5.0 cm的aTAA中瘤径与壁应力相关性差,个体化壁应力对评估夹层风险尤其重要。

核心结论

  • aTAA患者个体化峰值壁应力总体在≥5.0 cm组大于<5.0 cm组。
  • ≥5.0 cm组瘤径与峰值壁应力存在一定相关性,而<5.0 cm组相关性差。
  • 对<5.0 cm的aTAA,个体化壁应力对判断夹层风险尤其重要。

研究设计与样本

  • 研究纳入aTAA≥5.0 cm患者47例与<5.0 cm患者53例。
  • 采用心电门控CT获取个体化瘤体几何,网格化并确定预应力几何。
  • 用LS-DYNA有限元分析软件在收缩压下计算峰值壁应力与应力分布,材料模型为用户定义的纤维嵌入模型。

主要发现

  • 收缩压下峰值环向应力:≥5.0 cm组530±83 kPa,<5.0 cm组486±87 kPa(P=.07)。
  • 收缩压下峰值纵向应力:≥5.0 cm组331±57 kPa,<5.0 cm组310±54 kPa(P=.08)。
  • ≥5.0 cm组瘤径与峰值环向应力相关系数0.41,与峰值纵向应力相关系数0.33。
  • <5.0 cm组瘤径与峰值环向应力相关系数0.23,与峰值纵向应力相关系数0.14。

关键数值与推荐

  • 现行指南以动脉瘤尺寸作为升主动脉瘤择期手术风险分层的主要决定因素。
  • 生物力学上,当壁应力超过壁强度时可能发生夹层。

临床怎么用

  • 对<5.0 cm的aTAA,不宜仅凭瘤径评估夹层风险,可考虑结合个体化壁应力分析。
  • 对≥5.0 cm的aTAA,瘤径与峰值壁应力有一定相关性,但仍需个体化评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Current guidelines for elective surgery of ascending thoracic aortic aneurysms (aTAAs) use aneurysm size as primary determinant for risk stratification of adverse events. Biomechanically, dissection may occur when wall stress exceeds wall strength. Determining patient-specific aTAA wall stresses by finite element analysis can potentially predict patient-specific risk of dissection. This study compared peak wall stresses in patients with ≥5.0 cm versus <5.0 cm aTAAs to determine correlation between diameter and wall stress. METHODS: Patients with aTAA ≥5.0 cm (n = 47) and <5.0 cm (n = 53) were studied. Patient-specific aneurysm geometries obtained from echocardiogram-gated computed tomography were meshed and prestress geometries determined. Peak wall stresses and stress distributions were determined using LS-DYNA finite element analysis software (LSTC Inc, Livermore, Calif), with user-defined fiber-embedded material models under systolic pressure. RESULTS: Peak circumferential stresses at systolic pressure were 530 ± 83 kPa for aTAA ≥5.0 cm versus 486 ± 87 kPa for aTAA <5.0 cm (P = .07), whereas peak longitudinal stresses were 331 ± 57 kPa versus 310 ± 54 kPa (P = .08), respectively. For aTAA ≥5.0 cm, correlation between peak circumferential stresses and size was 0.41, whereas correlation between peak longitudinal wall stresses and size was 0.33. However, for aTAA <5.0 cm, correlation between peak circumferential stresses and size was 0.23, whereas correlation between peak longitudinal stresses and size was 0.14. CONCLUSIONS: Peak patient-specific aTAA wall stresses overall were larger for ≥5.0 cm than aTAA <5.0 cm. Although some correlation between size and peak wall stresses was found in aTAA ≥5.0 cm, poor correlation existed between size and peak wall stresses in aTAA <5.0 cm. Patient-specific wall stresses are particularly important in determining patient-specific risk of dissection for aTAA <5.0 cm.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Wang Z, Flores N, Lum M, et al. Wall stress analyses in patients with ≥5 cm versus <5 cm ascending thoracic aortic aneurysm. J Thorac Cardiovasc Surg. 2020. PMID: 32178922. doi:10.1016/j.jtcvs.2020.02.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。