文献速递瓣膜外科

小主动脉根患者使用快速释放主动脉瓣的单中心经验

Rapid-Deployment Aortic Valves for Patients With a Small Aortic Root: A Single-Center Experience.
PubMed 文献 · Ann Thorac Surg · 2020-03-21

该前瞻性单中心研究纳入659例接受快速释放瓣膜的重度主动脉瓣狭窄患者,其中217例(32.9%)置入19或21 mm小号瓣膜。

要点

  • 小主动脉根患者置入19/21 mm快速释放瓣膜后,1年及5年生存率良好。
  • 出院时平均跨瓣压差14.8 mmHg,有效瓣口面积1.55 cm²,PPM发生率35.5%。

核心结论

  • 小主动脉根患者使用快速释放瓣膜行外科主动脉瓣置换,血流动力学表现改善,PPM发生率降低。
  • 该亚组患者早中期生存率优异,心功能分级显著改善。

研究设计与样本

  • 其中217例(32.9%)置入19 mm或21 mm小号瓣膜,平均年龄74.9±7.9岁,女性占85.3%。

主要发现

  • 出院时和1年平均跨瓣压差分别为14.8±5.6 mmHg和13.6±4.9 mmHg。
  • 出院时平均有效瓣口面积为1.55±0.36 cm²,指数化有效瓣口面积为0.87±0.22 cm²/m²。
  • PPM发生于77例(35.5%),其中中度25.8%、重度9.7%。
  • 围术期死亡1.8%(4/217),1年和5年总体生存率分别为91%和79%。

临床怎么用

  • 对于小主动脉根的重度主动脉瓣狭窄患者,可考虑使用19或21 mm快速释放瓣膜,以改善血流动力学并降低PPM风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Aortic valve replacement in patients with a small aortic root is a matter of concern in terms of prosthesis-patient mismatch. We evaluated the survival and hemodynamic performance after implantation of a small rapid-deployment aortic valve (EDWARDS INTUITY valve system sizes 19 and 21 mm). METHODS: Between May 2010 and November 2018, 659 consecutive patients with severe aortic stenosis who received a rapid-deployment valve were included in a prospective and ongoing database. A small aortic bioprosthesis (sizes 19 mm and 21 mm) was implanted in 217 (32.9%) patients (mean age 74.9 ± 7.9 years, 85.3% women). Preoperative characteristics, operative parameters, and postoperative outcomes were assessed. RESULTS: Mean gradients at discharge and 1 year were 14.8 ± 5.6 mm Hg and 13.6 ± 4.9 mm Hg, respectively. Mean effective orifice area and the indexed effective orifice area at discharge were 1.55 ± 0.36 cm2 and 0.87 ± 0.22 cm2/m2, respectively, and prosthesis-patient mismatch occurred in 77 (35.5%) patients (25.8% moderate and 9.7% severe). Perioperative mortality was 1.8% (n = 4 of 217) and overall survival at 1 year and 5 years was 91% and 79%, respectively. The presence of any prosthesis-patient mismatch degree did not have a significant influence on overall survival (hazard ratio, 0.95; 95% confidence interval, 0.75-1.19; P = .638). At the last follow-up, mean New York Heart Association functional class was 1.5 ± 0.7 vs 2.8 ± 0.6 at baseline (P < .001). CONCLUSIONS: Surgical aortic valve replacement with rapid-deployment valves has shown improved results concerning hemodynamic performance, with decreased rates of prosthesis-patient mismatch. We observed excellent early-term and midterm survival and a significant improvement in functional class in this subgroup of patients with a small annulus.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Coti I, Haberl T, Scherzer S, et al. Rapid-Deployment Aortic Valves for Patients With a Small Aortic Root: A Single-Center Experience. Ann Thorac Surg. 2020. PMID: 32205113. doi:10.1016/j.athoracsur.2020.02.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。