PubMed 文献 · J Thorac Cardiovasc Surg · 2020-01-10

在10只羔羊和10只绵羊体内植入定制的脱细胞猪小肠黏膜下层带瓣管道行肺动脉瓣置换,评估其作为右心带瓣管道的表现。作者认为临床推广前需进一步分析这种两极分化的结果。

要点

  • 脱细胞猪小肠黏膜下层带瓣管道在动物模型中失败率高
  • 仅35%动物瓣膜功能良好且组织重塑迹象有限

核心结论

  • 35%动物见功能良好的瓣膜,但植入后≤3个月组织重塑迹象有限。
  • 临床推广前需进一步分析这一令人担忧的两极分化结果。

研究设计与样本

  • 在10只羔羊和10只绵羊中植入定制带瓣管道行肺动脉瓣置换。
  • 按1个月(3羔羊3绵羊)、3个月(3羔羊3绵羊)、6个月(4羔羊4绵羊)分组。
  • 植入后及处死前评估瓣膜功能,取出的管道行宏观、免疫组化、扫描电镜、力学及生化成分检测。

主要发现

  • 所有带瓣管道均成功植入。
  • 5只绵羊和2只羔羊术后2个月内死于充血性心力衰竭,死亡动物瓣叶增厚伴炎症征象(4例心内膜炎)。
  • 存活至计划随访者:1个月组6/6、3个月组4/6、6个月组3/8。
  • 处死时5只羔羊有显著肺动脉狭窄,1只绵羊重度反流。

局限性

  • 结论基于羔羊和绵羊异种动物模型,样本量有限且分组随访时间不一。
  • 作者明确指出临床推广前需进一步分析这一两极分化结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Decellularized extracellular matrix made from porcine small intestinal submucosa, commercially available as CorMatrix (CorMatrix Cardiovascular, Inc, Roswell, Ga) is used off-label to reconstruct heart valves. Recently, surgeons experienced failures and words of caution were raised. The aim of this study was to evaluate decellularized porcine small intestinal submucosa as right-sided heart valved conduit in a xenogeneic animal model. METHODS: A pulmonary valve replacement was performed with custom-made valved conduits in 10 lambs and 10 sheep (1 month [3 lambs and 3 sheep], 3 months [3 lambs and 3 sheep], 6 months [4 lambs and 4 sheep]). Valve function was assessed after implantation and before the animal was put to death. Explanted conduits were inspected macroscopically and analyzed using immunohistochemistry and scanning electron microscopy. They also underwent mechanical testing and testing for biochemical composition. RESULTS: All valved conduits were successfully implanted. Five sheep and 2 lambs died due to congestive heart failure within 2 months after surgery. In the animals that died, the valve leaflets were thickened with signs of inflammation (endocarditis in 4). Five sheep and 8 lambs (1 month: 6 out of 6 animals, 3 months: 4 out of 6 animals, 6 months: 3 out of 8 animals) survived planned follow-up. At the time they were put to death, 5 lambs had significant pulmonary stenosis and 1 sheep showed severe regurgitation. A well-functioning valve was seen in 4 sheep and 3 lambs for up to 3 months. These leaflets showed limited signs of remodeling. CONCLUSIONS: Fifty percent of sheep and 20% of lambs died due to valve failure before the planned follow-up period was complete. A well-functioning valve was seen in 35% of animals, albeit with limited signs of tissue remodeling at ≤3 months after implantation. Further analysis is needed to understand the disturbing dichotomous outcome before clinical application can be advised.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。