保留瓣膜的主动脉根部再植入联合瓣叶修复的中期结局
本研究采用面向修复的主动脉瓣反流分类系统,回顾1999至2018年197例择期行主动脉根部再植入患者,中位随访5.5年。10年免于主动脉瓣置换率为87.0±4.0%,免于瓣膜相关事件率为60.6±6.0%;Ib型反流结局优于III型。该分类有助于预测瓣膜修复技术的耐久性,患者选择对长期耐久性尤为重要。
要点
- 面向修复的AI分类可预测主动脉瓣修复的耐久性。
- Ib型AI患者10年免于瓣膜相关事件率优于III型。
- 二叶瓣II型与III型AI的5年免于瓣膜相关事件率差异显著。
核心结论
- 面向修复的主动脉瓣反流分类系统有助于预测耐久的主动脉瓣修复技术。
- 根据该分类进行患者选择对长期耐久性尤为重要。
研究设计与样本
- 回顾性单中心研究,1999至2018年共197例择期行主动脉根部再植入患者。
- 平均年龄52.7±17.7岁,男性占80%。
- 三叶瓣143例,二叶瓣51例,四叶瓣3例。
- I型AI 93例,II型AI 57例,III型AI 47例;264例中104例(39%)存在超过1种机制。
主要发现
- 院内死亡率为0.5%(1/197)。
- 中期随访平均5.5年,晚期死亡率为4.2%(9/197)。
- 16例(8.0%)行主动脉瓣再次手术。
- 10年免于主动脉瓣置换率为87.0±4.0%,免于主动脉瓣相关事件率为60.6±6.0%。
- Ib型AI患者10年免于主动脉瓣置换率98.3±1.7%、免于瓣膜相关事件率80.7±7.5%,优于III型AI的59.6±15.6%和42.2±13.1%(P=0.01)。
临床怎么用
- 术前可依据面向修复的AI分类评估瓣膜修复的长期耐久性。
- 对III型AI患者应更审慎评估修复策略的长期耐久性。
- 二叶瓣AI患者中II型与III型的5年结局存在差异,可用于咨询与决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Valve repair for aortic insufficiency (AI) requires a tailored surgical approach determined by the leaflet and aortic disease. In this study, we used a repair-oriented system for the classification of AI, and we elucidated long-term outcomes of aortic root reimplantation with this classification system. METHODS: From 1999 to 2018, a total of 197 patients underwent elective reimplantation (mean age: 52.7 ± 17.7 years; 80% male). The aortic valve was tricuspid in 143 patients, bicuspid in 51 patients and quadricuspid in 3 patients. A total of 93 patients had type I AI (aortic dilatation), 57 patients had type II AI (cusp prolapse) and 47 patients had type III AI (restrictive). In total, 104 of the 264 patients (39%) had more than 1 identified mechanism. RESULTS: In-hospital mortality was 0.5% (1/197). Mid-term follow-up (mean follow-up duration: 5.5 years) revealed a late mortality rate of 4.2% (9/197). Aortic valve reoperation was performed on 16 patients (8.0%). Rates of freedom from aortic valve replacement and freedom from aortic valve-related events at 10 years of follow-up were 87.0 ± 4.0% and 60.6 ± 6.0%, respectively; patients with type Ib AI (98.3 ± 1.7%; 80.7 ± 7.5%) had better outcomes than patients with type III AI (59.6 ± 15.6%; 42.2 ± 13.1%, P = 0.01). In patients with types II and III AI who had bicuspid aortic valves, rates of freedom from aortic valve-related events at 5 years of follow-up were 95.2 ± 4.7% and 71.7 ± 9.1%, respectively (P = 0.03). CONCLUSIONS: This repair-oriented system for classifying AI could help to predict the durable aortic valve repair techniques. Patient selection according to the classification is particularly important for long-term durability. CLINICAL TRIAL REGISTRATION NUMBER: B190050.
引用
- Yokawa K, Henmi S, Nakai H, et al. Mid-term outcomes of valve-sparing root reimplantation with leaflet repair. Eur J Cardiothorac Surg. 2020. PMID: 32187353. doi:10.1093/ejcts/ezaa058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。