文献速递瓣膜外科

主动脉瓣置换术后起搏器植入:快速部署Intuity®与常规生物瓣的比较

Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity® compared to conventional bioprostheses.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

本研究比较了快速部署生物瓣(RDB)与标准瓣膜行主动脉瓣置换术后永久起搏器(PPM)植入率。单中心2015-2018年924例患者中,RDB组PPM植入率14.5%,标准组3.9%(P<0.0001);倾向评分匹配后RDB组12.3% vs 标准组1.5%(P<0.0001)。RDB与PPM植入风险增加相关,但手术时间更短。

要点

  • 快速部署生物瓣术后PPM植入风险显著高于标准瓣膜(匹配后12.3% vs 1.5%)。
  • RDB组术后左束支传导阻滞和新发房颤发生率更高。
  • RDB组主动脉阻断时间和体外循环时间更短。

核心结论

  • 与标准主动脉瓣相比,快速部署生物瓣与起搏器植入风险增加相关,但手术时间缩短。

研究设计与样本

  • 单中心回顾性研究,纳入2015-2018年所有行主动脉瓣置换术的患者,共924例(RDB组256例,标准组668例),采用多因素分析和倾向评分匹配比较两组。

主要发现

  • 总体PPM植入67例,RDB组37例(14.5%),标准组26例(3.9%),P<0.0001(单变量分析)。
  • 多因素分析显示与PPM植入独立相关的因素:右束支传导阻滞(OR 3.7,95%CI 2.9-6.7;P<0.0001)、RDB(OR 3.6,95%CI 2.0-6.2;P<0.0001)、年龄(OR 1.1,95%CI 1.0-1.1;P<0.006)和心内膜炎(OR 3.4,95%CI 1.0-11.0;P<0.04)。
  • 倾向评分匹配后(每组203例),RDB组25例需PPM植入,标准组3例(12.3% vs 1.5%,P<0.0001)。
  • RDB组术后左束支传导阻滞和新发房颤更多(30.2% vs 5.1%,P<0.0001;34.0% vs 24.1%,P=0.029)。
  • RDB组手术时间更短:主动脉阻断时间62(44-76.5)min vs 72(57.5-91.5)min,体外循环时间81(63-98.5)min vs 91(75-112)min,P<0.0001。

临床怎么用

  • 临床选择快速部署生物瓣时应权衡起搏器植入风险增加与手术时间缩短的获益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The aim of this study was to compare the incidence of permanent pacemaker (PPM) implantation after aortic valve replacement by rapid-deployment bioprosthesis (RDB) and standard valve (Standard). METHODS: All patients undergoing aortic valve replacement between 2015 and 2018, in 1 centre, were included. A multivariate analysis on the whole cohort and then a propensity score matching were used to compare the 2 groups. The primary end point was PPM implantation. RESULTS: We studied 924 patients (256 RDBs and 668 Standards). Overall, 67 PPM were implanted, 37 (14.5%) in the RDB group and 26 (3.9%) in the Standard group (P < 0.0001, univariate analysis). The multivariate analysis in the unmatched population found 4 independent factors associated with PPM implantation: right bundle branch block with odds ratios (ORs 3.7, 95% CI 2.9-6.7; P < 0.0001), RDB (OR 3.6, 95% CI 2.0-6.2; P < 0.0001), age (OR 1.1, 95% CI 1.0-1.1; P < 0.006) and endocarditis (OR 3.4, 95% CI 1.0-11.0; P < 0.04). In the propensity score-matched RDB group (203 patients per group), 25 patients required PPM implantation versus 3 in the Standard group (12.3% vs 1.5%, P < 0.0001). RDBs also had more postoperative left bundle branch block and new onset of atrial fibrillation (30.2% vs 5.1%, P < 0.0001 and 34.0% vs 24.1%, P = 0.029). RDBs had lower operating times (in min): aortic cross-clamping = 62 (44-76.5) vs 72 (57.5-91.5) and cardiopulmonary bypass = 81 (63-98.5) vs 91 (75-112), P < 0.0001. There was no significant difference in other outcomes. CONCLUSIONS: RDBs were associated with reduced operating times, increased risk of atrial fibrillation and PPM implantation as compared with standard aortic valves.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Herry M, Laghlam D, Touboul O, et al. Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity® compared to conventional bioprostheses. Eur J Cardiothorac Surg. 2020. PMID: 32215660. doi:10.1093/ejcts/ezaa068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。