文献速递心外重症与机械循环支持

左心室辅助装置长期支持后脑MRI异常表现

Abnormalities of brain imaging in patients after left ventricular assist device support following explantation.
PubMed 文献 · J Heart Lung Transplant · 2019-11-29

本研究回顾2006至2016年连续流左心室辅助装置(LVAD)植入后因移植或恢复而撤除装置并接受脑MRI的患者,与年龄性别匹配的健康对照及慢性心力衰竭(CHF)患者比较。结果显示LVAD患者脑微出血(CMBs)和皮层表面铁沉积检出率显著更高,白质高信号严重程度高于健康对照但与CHF患者相似,脑萎缩定量指标亦显著更高,提示长期LVAD支持可能存在脑微血管损伤。

要点

  • LVAD撤除后患者脑微出血检出率高达98%,皮层表面铁沉积为31%。
  • LVAD患者脑微出血数量及脑萎缩定量指标高于健康对照和CHF患者。
  • 白质高信号严重程度高于健康对照,但与CHF患者相似。

核心结论

  • 长期LVAD支持患者脑微出血和皮层表面铁沉积患病率更高,脑萎缩更严重,提示脑微血管损伤。

研究设计与样本

  • 回顾性队列研究,纳入49例连续流LVAD植入后撤除装置并接受脑MRI的患者,另设49例年龄性别匹配健康对照和45例慢性心力衰竭患者。

主要发现

  • LVAD患者脑微出血检出率为98%(p < 0.001),皮层表面铁沉积检出率为31%(p < 0.001)。
  • LVAD患者脑微出血数量高于健康对照和CHF患者两组。
  • LVAD患者白质高信号严重程度高于健康对照,但与CHF患者相似。
  • LVAD患者脑萎缩定量分析显示双尾状核比和单元格指数显著高于两组对照。

临床怎么用

  • 长期LVAD支持患者撤除装置后应关注脑微血管损伤的影像学评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The potential impact of long-term left ventricular assist device (LVAD) support on the brain remains unclear. This study aimed to investigate cerebral microvascular damage in patients after long-term LVAD implantation using magnetic resonance imaging (MRI). METHODS: We reviewed the medical records of patients after continuous-flow LVAD implantation in our hospital from 2006 to 2016, who underwent brain MRI after LVAD explantation for either transplantation or recovery. Age- and sex-matched healthy controls and patients with chronic heart failure (CHF) were collected from our pooled MRI database. The presence of cerebral microbleeds (CMBs) and cortical superficial siderosis and the severity of white matter hyperintensity (WMH) and cerebral atrophy were compared between patients with prior LVAD and 2 control groups. RESULTS: This study included 49 patients with prior LVAD, 49 healthy controls, and 45 patients with CHF. CMBs and cortical superficial siderosis were detected in 98% (p < 0.001) and 31% (p < 0.001) of patients with prior LVAD, respectively. The number of CMBs was higher in patients with prior LVAD than in the 2 control groups. The severity of the WMH was higher in patients with prior LVAD than in healthy controls but similar to that in patients with CHF. Quantitative analyses of cerebral atrophy revealed a significantly higher bicaudate ratio and cella media index in patients with prior LVAD than in the 2 control groups. CONCLUSIONS: Patients after long-term LVAD support showed a higher prevalence of CMBs and cortical superficial siderosis and more severe cerebral atrophy than did controls. These findings may indicate cerebral microvascular damages in long-term LVAD support patients.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Murase S, Okazaki S, Yoshioka D, et al. Abnormalities of brain imaging in patients after left ventricular assist device support following explantation. J Heart Lung Transplant. 2019. PMID: 31843457. doi:10.1016/j.healun.2019.11.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。