新型主动脉带瓣管道体外评估:Valsalva窦等效结构改善瓣膜血流动力学
本研究在体外左心模拟器中,将含Valsalva窦等效结构的28-mm KONECT RESILIA主动脉带瓣管道与无窦部对照模型在3种心输出量下进行比较。结果显示,含窦部模型跨瓣压差更低、瓣叶开放更充分、有效和几何开口面积更大,并产生更大更稳定的涡流,促进更平滑的瓣膜关闭。
要点
- 含窦部带瓣管道在3种心输出量下平均和峰值跨瓣压差均低于无窦对照。
- 含窦部模型瓣叶开放更充分,有效和几何开口面积更大。
- 窦部结构促进更大更稳定涡流形成并维持至心动周期晚期,利于平滑关闭。
核心结论
- 含Valsalva窦等效结构的KONECT RESILIA主动脉带瓣管道可产生更大开口面积并改善瓣膜血流动力学,可能提升性能。
研究设计与样本
- 体外流动测试研究,使用28-mm KONECT RESILIA主动脉带瓣管道建立模型,以同型号无窦部带瓣管道为对照。
- 在已验证的左心模拟器中、3种心输出量水平下进行粒子图像测速和水动力学表征实验。
- 通过正面高速成像测定瓣叶运动学。
主要发现
- KONECT RESILIA模型在全部3种心输出量下平均和峰值跨瓣压差均低于对照模型。
- 其瓣叶较无窦部带瓣管道开放更充分,有效和几何开口面积更大。
- 窦部存在促进心动周期初期更大更稳定涡流形成,并有助于在心动周期晚期维持这些涡流,导致更平滑的瓣膜关闭。
临床怎么用
- 体外证据提示含Valsalva窦等效结构的带瓣管道可能改善瓣膜血流动力学和瓣叶运动学。
- 该结果支持在临床选择带瓣管道时考虑窦部结构对血流动力学的潜在益处。
局限性
- 本研究为体外模拟器实验,不能直接等同于体内血流动力学表现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study examined whether the presence of a sinus of Valsalva equivalent in the KONECT RESILIA aortic valved conduit (Edwards Lifesciences, Irvine, Calif) improves valve hemodynamics, kinematics, and performance. METHODS: A 28-mm KONECT RESILIA aortic valved conduit was used to create an in vitro flow test model, and the same aortic valved conduit model without a sinus section was used as a control. Particle image velocimetry and hydrodynamic characterization experiments were conducted in the vicinity of the valves in a validated left-heart simulator at 3 cardiac output levels. In addition, leaflet kinematics of the valves were determined through en face high-speed imaging. RESULTS: The KONECT RESILIA aortic valved conduit model exhibited lower mean and peak transvalvular pressure gradients than the control model at all 3 cardiac outputs. In addition, its leaflets opened more fully than did those of the valved conduit without the sinuses, yielding greater effective and geometric orifice areas. It was found that the presence of the sinuses not only facilitated the development of larger and more stable vortices at the initial stages of the cardiac cycle but also helped to maintain these vortices during the late stages of the cardiac cycle, leading to smoother valve closure. CONCLUSIONS: The KONECT RESILIA aortic valved conduit reproduces the bulged section of the aortic root corresponding to the sinuses of Valsalva. With this Valsalva-type conduit, larger orifice areas were observed, improving valve hemodynamics that may enhance performance.
引用
- Sadri V, Madukauwa-David ID, Yoganathan AP, et al. In vitro evaluation of a new aortic valved conduit. J Thorac Cardiovasc Surg. 2019. PMID: 31879167. doi:10.1016/j.jtcvs.2019.09.181
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。