文献速递肺外科

超声能量在胸腔镜肺叶切除术中闭合肺动脉分支的前瞻性多中心二期试验

Prospective, multicenter, international phase 2 trial evaluating ultrasonic energy for pulmonary artery branch sealing in video-assisted thoracoscopic surgery lobectomy.
PubMed 文献 · J Thorac Cardiovasc Surg · 2019-09-30

这项前瞻性、多中心、国际二期临床试验评估了超声血管闭合装置在微创解剖性肺切除中闭合肺动脉分支的近期与中期有效性和安全性,纳入150例患者,共离断424支肺动脉分支,其中239支使用超声装置,181支使用内镜吻合器,4支使用内镜夹;超声组术中出血率为1.3%,吻合器组为2.2%,术后无分割血管出血,30天无死亡,结论认为对7 mm及以下肺动脉分支超声闭合是安全的。

要点

  • 超声血管闭合装置可用于胸腔镜肺叶切除术中7 mm及以下肺动脉分支的闭合离断。
  • 超声组术中出血率1.3%(3/239支),吻合器组2.2%(4/181支),术后两组均无分割血管出血。
  • 30天无死亡,密封失败患者中1例需中转开胸。

核心结论

  • 胸腔镜肺叶切除术中使用超声能量闭合7 mm及以下肺动脉分支是安全的,超声装置是合理的闭合方法。

研究设计与样本

  • 前瞻性、二期、多中心、国际临床试验(NCT02719717),在7个中心(美国、加拿大、英国)纳入计划行胸腔镜/机器人解剖性肺切除的患者。
  • 共纳入150例患者,其中139例肺叶切除、11例肺段切除;肺动脉分支直径≤7 mm者用超声血管闭合装置闭合离断。

主要发现

  • 共离断424支肺动脉分支:超声装置239支、内镜吻合器181支、内镜夹4支。
  • 超声组平均/中位肺动脉直径为4.7 mm/5.0 mm,吻合器组为10.3 mm/10.0 mm,内镜夹组为6.5 mm/6.5 mm。
  • 超声组3支(1.3%)和吻合器组4支(2.2%)术中出血;密封失败患者中1例需中转开胸。
  • 两种闭合方法术后均无分割肺动脉分支出血,30天无死亡。

关键数值与推荐

  • 超声血管闭合装置适用于直径≤7 mm的肺动脉分支闭合离断。

临床怎么用

  • 在胸腔镜肺叶切除术中,对7 mm及以下肺动脉分支可选用超声血管闭合装置进行闭合离断。

局限性

  • 原文未报告随机对照设计,为单臂二期试验,样本量150例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The study objectives were to evaluate the immediate, short-, and medium-term efficacy and safety of pulmonary artery branch sealing using an ultrasonic vessel-sealing device in minimally invasive anatomic lung resection. METHODS: This study consists of a prospective, phase 2, multicenter, international clinical trial (clinicaltrials.gov: NCT02719717) that enrolled patients planned for video-assisted thoracoscopic surgery/robotic anatomic lung resection in 7 centers (United States, Canada, United Kingdom). Pulmonary artery branches of 7 mm or less were sealed and divided with an ultrasonic energy vessel-sealing device. The remainder of the lobectomy was performed according to surgeon preference. Intraoperative, in-hospital, and 30-day postoperative bleeding and complications were prospectively recorded. RESULTS: A total of 150 patients with a minimum of 1 pulmonary artery branch sealed with an ultrasonic vessel-sealing device were prospectively enrolled in the trial. Resections included 139 lobectomies and 11 segmentectomies. A total of 424 pulmonary artery branches were divided: 239 with the ultrasonic vessel-sealing device, 181 with endostaplers, and 4 with endoscopic clips. The mean and median pulmonary artery diameters were 4.7 mm/5.0 mm, 10.3 mm/10.0 mm, and 6.5 mm/6.5 mm for each method, respectively. Three of the pulmonary artery branches divided with the ultrasonic vessel-sealing device (1.3%) and 4 pulmonary artery branches divided with endostaplers (2.2%) bled intraoperatively. Among the patients with seal failures, 1 patient required conversion to thoracotomy. There was no postoperative bleeding from divided pulmonary artery branches with either sealing method. There was no mortality at 30 days. CONCLUSIONS: Pulmonary artery branch sealing with ultrasonic energy during video-assisted thoracoscopic surgery lobectomy is safe for vessels 7 mm or less. The use of an ultrasonic device is a reasonable sealing method for pulmonary artery branches 7 mm or less.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Liberman M, Goudie E, Morse C, et al. Prospective, multicenter, international phase 2 trial evaluating ultrasonic energy for pulmonary artery branch sealing in video-assisted thoracoscopic surgery lobectomy. J Thorac Cardiovasc Surg. 2019. PMID: 31679701. doi:10.1016/j.jtcvs.2019.09.061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。