三尖瓣成形环对羊三尖瓣环几何与运动学的影响

The influence of tricuspid annuloplasty prostheses on ovine annular geometry and kinematics.
PubMed 文献 · J Thorac Cardiovasc Surg · 2019-09-28

结果显示柔性环和混合环更好地保留了瓣环动态与应变,而刚性环维持了三维几何。这些数据可能有助于优化三尖瓣成形环设计并提高瓣膜修复耐久性。

要点

  • 柔性Duran AnCore环和混合Tri-Ad Adams带允许瓣环面积动态变化,而刚性Contour 3D环显著受损。
  • 所有成形环均降低瓣环周长缩短和收缩期全局应变,刚性环影响最大。
  • 刚性环维持瓣环高度,而柔性和混合环降低瓣环高度。

核心结论

  • 在健康羊心脏中,柔性和混合环更好地保留了瓣环动态和应变,而刚性环维持了三维几何。

主要发现

  • 瓣环面积收缩在对照组为11%±3%,Contour 3D环显著受损为2%±1%,Duran AnCore环和Tri-Ad Adams带分别为9%±3%和8%±4%。

临床怎么用

  • 选择三尖瓣成形环时需权衡瓣环动态保留与三维几何维持,柔性或混合环可能更利于保留瓣环运动。

局限性

  • 研究在健康羊心脏中急性开放胸条件下进行,未模拟功能三尖瓣反流病理状态,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Surgical repair of functional tricuspid regurgitation is centered on annular reduction with artificial rings; however, the precise effect of prosthesis implantation on annular geometry, dynamics, and strain is unknown. METHODS: Forty healthy sheep had sonomicrometry crystals implanted around the tricuspid annulus and onto right ventricle free wall. Ten animals underwent tricuspid annuloplasty with a flexible Duran AnCore ring (Medtronic, Minneapolis, Minn) (28 ± 1 mm), 10 with Contour 3D rigid ring (Medtronic) (29 ± 1 mm), 10 with hybrid Tri-Ad Adams band (Medtronic) (28 ± 1 mm), and 10 had no prosthesis (control group). Pressure sensors were inserted in the left ventricle, right ventricle, and right atrium. Data were acquired with open chest after weaning off cardiopulmonary bypass and hemodynamic stabilization. Annular area, global and regional contraction, height, and strain were calculated based on cubic spline fits to crystal locations. RESULTS: Tricuspid annular area contraction during the cardiac cycle was 11% ± 3% in the control group. The Contour 3D ring significantly impaired annular contraction (2% ± 1%) whereas the Duran AnCore ring and Tri-Ad Adams band (9% ± 3% and 8% ± 4%, respectively) permitted dynamic area change. Global perimeter reduction was 6% ± 1% in the control group and decreased in the Duran AnCore (3% ± 1%), Contour 3D (0.4% ± 0.2%), and Tri-Ad Adams (3% ± 1%) groups (all P values < .001 vs control). Annular height was 6.2 ± 2.0 mm in the control group, unchanged in the Contour 3D (4.9 ± 1.1 mm) but reduced in the Duran AnCore (3.1 ± 1.3 mm) and Tri-Ad Adams (3.1 ± 1.0 mm) groups (P < .001 Duran AnCore and Tri-Ad Adams vs control). Rings perturbed systolic global annular strain (control, 5.3% ± 1.8%; Duran AnCore, 2.3% ± 1.0%; Contour 3D, 0.6% ± 0.2%; and Tri-Ad Adams, -2.6% ± 0.7%) with Contour 3D inducing the biggest change (P < .05 vs other groups). CONCLUSIONS: In healthy ovine hearts, flexible and hybrid rings better preserved annular dynamics and strain, whereas the rigid ring maintained 3-dimensional geometry. These data may aid the design of optimal tricuspid annular prostheses and improve durability of valve repair.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Malinowski M, Jazwiec T, Quay N, et al. The influence of tricuspid annuloplasty prostheses on ovine annular geometry and kinematics. J Thorac Cardiovasc Surg. 2019. PMID: 31733883. doi:10.1016/j.jtcvs.2019.09.060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。