文献速递主动脉外科瓣膜外科

二叶式主动脉瓣主动脉病变具有独特的基质降解模式

Bicuspid valve aortopathy is associated with distinct patterns of matrix degradation.
PubMed 文献 · J Thorac Cardiovasc Surg · 2019-09-25

该研究比较了二叶式主动脉瓣动脉瘤(BAV-A)、三叶式主动脉瓣特发性退行性动脉瘤(DA)与正常主动脉在微力学、生化和微结构上的差异。BAV-A 的弹性模量较对照组和 DA 高 20% 以上,提示顺应性丧失更明显;虽然各组弹性蛋白水平无差异,但 BAV-A 中弹性蛋白在中膜内压实,呈现独特的基质降解空间分布。

要点

  • BAV-A 主动脉壁弹性模量较对照组和 DA 增加 20% 以上,顺应性丢失更显著。
  • BAV-A 与 DA 胶原水平均高于对照组,但弹性蛋白与糖胺聚糖总量无组间差异。
  • BAV-A 弹性蛋白在中膜内压实,DA 则高度碎片化,空间分布模式不同。

核心结论

  • BAV-A 相对 DA 和对照组存在更明显的主动脉壁顺应性丧失。
  • 尽管各组弹性蛋白总量相等,BAV-A 的弹性蛋白空间分布呈现独特的基质降解特征。

研究设计与样本

  • 获取动脉瘤修复手术患者的主动脉组织(BAV-A n=15,DA n=15)。
  • 对照组织来自冠状动脉旁路移植术中的主动脉冲孔活检(n=9)。
  • 采用纳米压痕测定中膜弹性模量,生化法测糖胺聚糖、胶原和弹性蛋白水平,Verhoeff Van Gieson 染色切片定量弹性蛋白微结构。

主要发现

  • BAV-A 弹性模量较对照组和 DA 高 20% 以上,对照组与 DA 间无显著差异。
  • 胶原水平:BAV-A 36.9 ± 7.4 μg/mg,DA 49.9 ± 10.9 μg/mg,均高于对照组 30.2 ± 13.1 μg/mg。
  • 糖胺聚糖和弹性蛋白水平组间无显著差异。
  • 对照组弹性蛋白段分布均匀;动脉瘤组织靠近内膜和外膜层弹性蛋白段减少。
  • BAV-A 和 DA 中膜内弹性蛋白段均压实,但 DA 中弹性蛋白段高度碎片化。

临床怎么用

  • BAV-A 患者主动脉壁顺应性丢失更显著,提示其动脉瘤进展机制可能不同于 DA。
  • 弹性蛋白空间分布模式差异或可辅助区分 BAV-A 与 DA 的基质降解特征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To explore the micromechanical, biochemical, and microstructural differences between bicuspid aortic valve aneurysm (BAV-A) and tricuspid aortic valve idiopathic degenerative aneurysm (DA), compared with normal aorta. METHODS: Aortic tissue was obtained from patients undergoing aneurysmal repair surgery (BAV-A; n = 15 and DA; n = 15). Control tissue was obtained from aortic punch biopsies during coronary artery bypass graft surgery (n = 9). Nanoindentation was used to determine the elastic modulus on the medial layer. Glycosaminoglycan, collagen, and elastin levels were measured using biochemical assays. Verhoeff Van Gieson-stained cross-sections were imaged for elastin microstructural quantification. RESULTS: The elastic modulus was more than 20% greater for BAV-A relative to control and DA (signifying a loss of compliance). No significance difference between control and DA were observed. Collagen levels for BAV-A (36.9 ± 7.4 μg/mg) and DA (49.9 ± 10.9 μg/mg) were greater compared with the control (30.2 ± 13.1 μg/mg). Glycosaminoglycan and elastin levels were not significant between the groups. Elastin segments were uniform throughout the control. Aneurysmal tissues had less elastin segments close to the intima and adventitia layers. Both BAV-A and DA had elastin segments compacted in the media; however, elastin segments were highly fragmented in DA. CONCLUSIONS: BAV-A has a greater loss of aortic wall compliance relative to DA and the control. Although elastin levels were equal for all groups, spatial distribution of elastin provided a unique profile of matrix degradation for BAV-A. Elastin compaction within the media of BAV-A may have resulted from the altered hemodynamic pressure against the wall, which could explain for the stiffness of the tissue.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Chim YH, Davies HA, Mason D, et al. Bicuspid valve aortopathy is associated with distinct patterns of matrix degradation. J Thorac Cardiovasc Surg. 2019. PMID: 31679706. doi:10.1016/j.jtcvs.2019.08.094

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。