EHRA国际共识:心脏植入电子装置感染的预防、诊断与治疗
该共识由EHRA联合HRS、APHRS、LAHRS、ISCVID及EACTS制定,针对起搏器、ICD和CRT装置感染风险,汇总风险评估、预防、诊断与治疗建议。基于重要随机试验及全球调查发现的实践差异,文件旨在规范临床管理并明确中心与术者最低质量要求。
要点
- 植入前静脉抗生素是公认的预防措施。
- 皮肤消毒剂、囊袋抗生素溶液等预防措施证据尚不明确。
- 共识强调中心与术者最低质量要求及手术量标准。
核心结论
- 该国际共识文件针对CIED感染的风险评估、预防、诊断和治疗提供指导,并强调中心与术者最低质量要求及手术量标准。
研究设计与样本
- 由EHRA联合HRS、APHRS、LAHRS、ISCVID及EACTS制定的2019国际最新共识文件。
主要发现
- CIED感染与显著发病率、住院增加、生存率降低和医疗成本增加相关。
- 植入前静脉抗生素预防已获公认,但皮肤消毒剂、囊袋抗生素溶液、抗菌封套、植入后延长抗生素等作用仍存不确定性。
- 关于新型低感染风险装置替代品和新型口服抗凝药的使用指导有限。
临床怎么用
- 临床应重视CIED感染的预防,遵循共识推荐的风险评估、诊断与治疗路径。
- 在缺乏明确证据的预防措施上,需结合共识建议与患者具体情况决策。
局限性
- 多种预防、诊断和治疗措施的证据尚不明确,相关指导有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially life-saving treatments for a number of cardiac conditions, but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased healthcare costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. Guidance on whether to use novel device alternatives expected to be less prone to infections and novel oral anticoagulants is also limited, as are definitions on minimum quality requirements for centres and operators and volumes. Moreover, an international consensus document on management of CIED infections is lacking. The recognition of these issues, the dissemination of results from important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.
引用
- Blomström-Lundqvist C, Traykov V, Erba PA, et al. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg. 2020. PMID: 31724720. doi:10.1093/ejcts/ezz296
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。