文献速递瓣膜外科

基于三角的瓣环成形环尺寸选择新方法

Novel Trigone-Based Sizing Method for Mitral Ring Annuloplasty.
PubMed 文献 · Ann Thorac Surg · 2019-10-03

该研究提出一种基于三角的尺寸选择方法,将三角置于瓣环周长的四分之一处,用于二尖瓣成形术。

要点

  • 基于三角的尺寸选择法在多数MR患者中实现了满意的MR控制。
  • 退行性组中观察/三角间距预测直径比<0.9者SAM发生率为10%。
  • 观察/BSA预测直径比与平均跨二尖瓣压差呈负相关。

核心结论

  • 基于三角的尺寸选择方法在二尖瓣成形术中实现了满意的MR控制,同时避免功能性二尖瓣狭窄和SAM。

研究设计与样本

  • 单中心回顾性研究,1999至2017年纳入436例退行性(n=192)、非缺血性功能性(n=124)或缺血性(n=120)MR患者,均使用不完整成形环行二尖瓣成形术。

主要发现

  • 初次修复成功433例(99%),3例因SAM和MR转为瓣膜置换。

关键数值与推荐

  • 三角置于瓣环周长的四分之一处作为尺寸选择基准。

临床怎么用

  • 该尺寸选择方法可用于二尖瓣成形术中指导成形环选择,以控制MR复发并减少功能性二尖瓣狭窄和SAM。

局限性

  • 原文未报告

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We devised a novel trigone-based sizing method, setting the trigones at one-quarter of the annular circumference, and used it for mitral annuloplasty in patients with mitral regurgitation (MR). METHODS: Between 1999 and 2017, 436 patients with degenerative (n = 192), nonischemic functional (n = 124), or ischemic (n = 120) MR underwent mitral valvuloplasty at our institution using an incomplete ring. The intertrigonal distance and prerepair and postrepair annular diameter were measured. Then the diameters predicted from body surface area, the intertrigonal distance, and the ratios of these diameters to observed data were computed. We investigated the influence of these measurements on MR recurrence, transmitral pressure gradient, and systolic anterior motion. RESULTS: Initial repair was successful in 433 patients (99%), but 3 patients with systolic anterior motion and MR required conversion to valve replacement. After 1, 5, and 10 years (mean follow-up, 6.3 years), the rate of freedom from grade 2 or higher recurrent MR was 96%, 92%, and 86% in the degenerative group, 99%, 97%, and 90% in the nonischemic functional group, and 95%, 90%, and 79%, respectively, in the ischemic group (P = .052). The observed/body surface area predicted diameter ratio was negatively correlated with the mean transmitral pressure gradient (mm Hg); 12.3 - 8.2 × (ratio) (R = -0.37, P < .001), despite a smaller ratio (<0.9) not being associated with less recurrence of MR. In the degenerative group, systolic anterior motion developed in 7 of 71 patients (10%) with an observed/intertrigonal distance predicted diameter ratio of less than 0.9 (P < .001). CONCLUSIONS: Our trigone-based sizing method achieved satisfactory control of MR, while avoiding functional mitral stenosis and systolic anterior motion.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Okamoto H, Fujimoto Y, Teramoto C, et al. Novel Trigone-Based Sizing Method for Mitral Ring Annuloplasty. Ann Thorac Surg. 2019. PMID: 31586611. doi:10.1016/j.athoracsur.2019.08.085

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。