主动脉瓣置换缝合技术对人工瓣膜-患者不匹配的影响
本研究回顾性分析439例主动脉瓣置换患者,比较带垫片间断褥式、无垫片间断褥式和8字无垫片缝合三种技术。无垫片间断褥式缝合在小主动脉瓣环(18-21 mm)患者中显著降低中度和重度人工瓣膜-患者不匹配发生率,且不增加住院死亡或心脏不良事件。
要点
- 无垫片间断褥式缝合可减少小瓣环(18-21 mm)患者的中度和重度PPM。
- 三种缝合技术的住院死亡和心脏不良事件无差异。
- 无垫片间断褥式缝合实现完全瓣上植入,改善血流动力学。
核心结论
- 无垫片间断褥式缝合提供完全瓣上植入,降低小尺寸主动脉瓣置换后PPM发生率并改善血流动力学。
研究设计与样本
- 回顾性分析2015年1月至2018年9月在本机构接受主动脉瓣置换的439例患者,比较三种缝合技术的术前临床信息和术后1年血流动力学数据。
关键数值与推荐
- 小主动脉瓣环定义为18至21 mm。
临床怎么用
- 小主动脉瓣环(18-21 mm)患者行主动脉瓣置换时,可优先考虑无垫片间断褥式缝合以降低PPM风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). METHODS: Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). RESULTS: A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). CONCLUSIONS: The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR.
引用
- Kim HH, Lee S, Joo HC, et al. Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch. Ann Thorac Surg. 2019. PMID: 31604093. doi:10.1016/j.athoracsur.2019.09.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。