单侧上半胸骨切开行全主动脉弓置换治疗A型夹层
本研究回顾性分析153例急性A型主动脉夹层行全弓置换加冷冻象鼻支架植入患者,其中73例采用单侧上半胸骨切开(UHS),80例采用全胸骨切开(FS)。结论认为UHS入路安全且切口更美观。
要点
- 两组术前及术中变量无显著差异,UHS入路安全可行。
核心结论
- 单侧上半胸骨切开行全弓置换加冷冻象鼻支架植入治疗急性A型夹层安全,且切口更美观。
研究设计与样本
- 回顾性分析2016年5月至2018年4月162例连续急性A型夹层行全弓置换加冷冻象鼻支架植入患者,最终纳入153例,分为UHS组(n=73)和FS组(n=80)。
主要发现
- 两组任何术前或术中变量均无显著差异。
临床怎么用
- 对于急性A型主动脉夹层需行全弓置换加冷冻象鼻支架植入的患者,可考虑采用单侧上半胸骨切开入路,以期缩短机械通气时间、减少早期引流量并改善切口美观。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: An upper hemisternotomy (UHS) tends to be performed for aortic valve replacement. However, the safety of UHS for total arch replacement combined with frozen elephant trunk implantation in patients with acute type A dissections is ambiguous. METHODS: We retrospectively analyzed 162 consecutive patients with acute type A dissections who underwent total arch replacement combined with frozen elephant trunk implantation between May 2016 and April 2018. A total of 153 patients enrolled were included, divided into the UHS group (n = 73, single upper hemisternotomy) and full sternotomy (FS) group (n = 80). Perioperative characteristics were recorded. RESULTS: There was no significant difference in any preoperative or intraoperative variables between groups. However, ventilation times (18 hours [range, 12-303 hours] versus 20.5 hours [range, 3-244 hours]; P = .002) were significantly shorter in the UHS group compared with the FS one. Results for the first 24 hours of chest tube drainage (160 mL [range, 70-700] versus 267.5 mL [range, 10-1,455 mL]; P = .001) were significantly less in the UHS group than the FS group. CONCLUSIONS: Total arch replacement combined with frozen elephant trunk implantation through a single upper-hemisternotomy approach in patients with acute type A dissections is a safe procedure that adds the benefit of a more cosmetic incision.
引用
- Jiang H, Liu Y, Yang Z, et al. Total Arch Replacement via Single Upper-Hemisternotomy Approach in Patients With Type A Dissection. Ann Thorac Surg. 2019. PMID: 31589853. doi:10.1016/j.athoracsur.2019.08.095
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。