文献速递先天性心脏病外科主动脉外科

法洛四联症修复术后主动脉血流传导异常与黏性能量损失增加相关

Abnormal aortic flow conduction is associated with increased viscous energy loss in patients with repaired tetralogy of Fallot.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

结果显示TOF组胸主动脉峰值和平均EL'显著升高,且EL'与左心室射血分数及心室收缩末期容积相关,提示主动脉血流效率降低可能影响长期心功能。

要点

  • TOF修复术后患者胸主动脉峰值和平均黏性能量损失显著高于健康对照。
  • 升主动脉收缩期峰值EL'在TOF组是对照组的2倍。
  • EL'与左心室射血分数及左右心室收缩末期容积相关。

核心结论

  • 法洛四联症修复术后患者存在主动脉血流异常,表现为胸主动脉黏性能量损失增加。
  • EL'的幅度与左心室功能及心室容积相关,可能增加心脏做功并影响长期心功能。

主要发现

  • TOF组胸主动脉峰值收缩期EL'为3.8 mW,对照组为1.5 mW(P=0.004)。
  • TOF组全心动周期平均EL'为1.2 mW,对照组为0.5 mW(P=0.003)。
  • 升主动脉收缩期峰值EL'在TOF组为2.0 mW,对照组为0.9 mW(P=0.007),增加2倍。
  • 全胸主动脉长度峰值EL'与左心室射血分数相关(R=-0.45,P=0.009)。
  • 峰值EL'与指数化左心室收缩末期容积(R=-0.40,P=0.010)和右心室收缩末期容积(R=-0.37,P=0.034)相关。

临床怎么用

  • 对于TOF修复术后主动脉尺寸正常的患者,应关注主动脉血流效率异常及其对心室功能的潜在影响。
  • 四维血流磁共振测量的EL'可作为评估TOF患者主动脉血流效率和心功能关联的参考指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Aortopathy in tetralogy of Fallot (TOF) is characterized by increased aortic stiffness, dilation and reduced left ventricular (LV) function. Repair in infancy normalizes aortic dimensions in early childhood. Our prior work demonstrated that early TOF repair does not normalize aortic compliance and that abnormal ascending aortic flow patterns are prevalent. The objectives of this study were to: (i) determine whether proximal aortic flow-mediated viscous energy loss (EL') is elevated in patients with early TOF repair compared with healthy controls, and (ii) determine whether the degree of EL' is associated with LV function. METHODS: Forty-one patients post TOF repair with normalized aortic size and 15 healthy controls underwent 4-dimenisonal-flow magnetic resonance imaging flow analysis and EL' assessment. Correlations between EL', aortic size, and LV function were assessed. RESULTS: The TOF group had increased peak systolic thoracic aorta EL' (3.8 vs 1.5 mW, P = 0.004) and increased averaged EL' throughout the cardiac cycle (1.2 vs 0.5 mW, P = 0.003). Peak and mean systolic EL' in the ascending aorta was increased 2-fold in the TOF group compared with control (peak: 2.0 vs 0.9 mW, P = 0.007). Peak EL' measured along the entire thoracic aortic length correlated with LV ejection fraction (R = -0.45, P = 0.009), indexed LV end-systolic volume (R = -0.40, P = 0.010), and right ventricular end-systolic volume (R = -0.37, P = 0.034). CONCLUSIONS: Patients with repaired TOF exhibit abnormal aortic flow associated with increased EL' in the thoracic aorta. The magnitude of EL' is associated with LV function and volumes. Increased aortic EL' in TOF is likely due to inherently abnormal LV outflow geometry and or right ventricular interaction. Reduced aortic flow efficiency in TOF increases cardiac work and may be an important factor in long-term cardiac performance.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Schäfer M, Barker AJ, Jaggers J, et al. Abnormal aortic flow conduction is associated with increased viscous energy loss in patients with repaired tetralogy of Fallot. Eur J Cardiothorac Surg. 2020. PMID: 31535124. doi:10.1093/ejcts/ezz246

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。