文献速递主动脉外科

B型主动脉夹层TEVAR术后假腔血栓化的角度预测指标

Predictor of false lumen thrombosis after thoracic endovascular aortic repair for type B dissection.
PubMed 文献 · J Thorac Cardiovasc Surg · 2019-08-25

本研究基于48例急性B型主动脉夹层患者TEVAR术后的CT影像重建主动脉几何形态,提出「问号角度(φ)」描述主动脉弓形态,并分析其与假腔血栓化率(FLTR)的关系。结果显示问号角度与FLTR呈负相关,并建立线性预测模型,另用10例患者验证。结论认为问号角度越大,假腔越不易形成完全血栓。

要点

  • 问号角度与TEVAR术后假腔血栓化率呈负相关
  • 角度越大,假腔越难形成完全血栓
  • 所建线性模型在10例患者中验证一致

核心结论

  • 问号形态的大小可能是急性B型主动脉夹层TEVAR术后FLTR的良好预测指标,问号角度越大越不易形成完全血栓。

研究设计与样本

  • 从48例急性B型主动脉夹层患者(平均年龄48岁)TEVAR术后CT图像重建主动脉几何形态,提出问号角度φ,并用血流动力学参数分析主动脉成角对FLTR的影响,另选10例患者验证预测模型。

主要发现

  • 问号形态程度与FLTR呈负相关(n=38;P<.001;R=-0.661)。
  • 建立线性关系模型:FLTR(%)=-1.955×φ+168.24(R2=0.437;P<.001)。
  • 通向假腔的净流量随问号形态程度增加而显著增加。
  • 预测模型的差异与一致性在剩余10例患者中经配对样本t检验和一致性相关系数验证良好。

关键数值与推荐

  • 问号形态程度与FLTR负相关:n=38,P<.001,R=-0.661。
  • 预测模型:FLTR(%)=-1.955×φ+168.24,R2=0.437,P<.001。

临床怎么用

  • TEVAR术前可测量主动脉问号角度,用于预估假腔血栓化可能性并辅助风险评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Thoracic endovascular aortic repair of type B aortic dissection initiates thrombosis in the false lumen, which eventually results in aortic remodeling. We aimed to determine whether the false lumen thrombosis rate (FLTR) after thoracic endovascular aortic repair can be accurately predicted by an index that expresses the degree of aortic arch angulation. METHODS: The geometry of 48 patients with acute type B aortic dissection (mean age, 48 years) after thoracic endovascular aortic repair was reconstructed from postoperative computed tomography images. We introduced a novel angle-the degree of question mark (φ)-to indicate the aortic morphology. Moreover, how aortic angulation influenced the FLTR was investigated based on hemodynamic parameters. Finally, a predicted mathematical model relating FLTR to aortic angulation was proposed, and 10 patients were chosen to validate the model. RESULTS: The degree of question mark shape was shown to negatively correlate with FLTR (n = 38; P < .001; R = -0.661), and the linear relationship model was created as follows: FLTR (%) = -1.955 × φ + 168.24 (R2 = 0.437; P < .001). In addition, the net flow rate to the false lumen significantly increased with the increase of the degree of the question mark shape of the aorta. Furthermore, the difference and concordance of the proposed prediction model were perfectly validated in the remaining 10 patients using paired-sample t test and the concordance correlation coefficient. CONCLUSIONS: The size of the question mark shape may be a good predictor for FLTR of acute type B aortic dissection following thoracic endovascular aortic repair. The higher the degrees of the question mark, the less likely it was to form a complete thrombus.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Li D, Peng L, Wang Y, et al. Predictor of false lumen thrombosis after thoracic endovascular aortic repair for type B dissection. J Thorac Cardiovasc Surg. 2019. PMID: 31558276. doi:10.1016/j.jtcvs.2019.07.091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。