主动脉瓣置换术中体外循环对心肌水通道蛋白表达的影响
本研究对17例重度主动脉瓣狭窄行主动脉瓣置换术的患者,在体外循环前后取左心室心肌活检,检测水通道蛋白1和4的表达。结果显示体外循环后水通道蛋白1蛋白水平平均升高约62%(P=0.001),水通道蛋白4平均降低约38%(P=0.030),心肌间质水肿增加42%(95%CI 31-54%),且发生低心排综合征的患者水通道蛋白表达变化位于中位数上半区。结论提示水通道蛋白表达的时间依赖性变化可能与体外循环相关的心肌水肿和功能障碍有关。
要点
- 体外循环后心肌水通道蛋白1升高约62%,水通道蛋白4降低约38%。
- 体外循环期间水通道蛋白1以1.7%/min增加,水通道蛋白4以2.5%/min减少。
- 低心排综合征患者水通道蛋白表达变化幅度较大。
核心结论
- 心脏水通道蛋白表达的时间依赖性变化可能与体外循环相关的心肌水肿和功能障碍有关。
研究设计与样本
- 连续纳入17例重度主动脉瓣狭窄行主动脉瓣置换术的患者,在体外循环前后各取左心室心肌活检,进行Western blot和免疫组化研究。
主要发现
- 体外循环后水通道蛋白1蛋白水平平均升高约62%(P=0.001),水通道蛋白4平均降低约38%(P=0.030)。
- 免疫组化显示水通道蛋白1沿小血管分布,水通道蛋白4在心肌细胞呈环形标记,体外循环后两者定位无变化。
- 体外循环期间水通道蛋白1平均以1.7%/min增加(P=0.021),水通道蛋白4以2.5%/min减少(P=0.018)。
- 体外循环后心肌间质水肿增加42%(95%CI 31-54%)。
- 发生低心排综合征的患者水通道蛋白表达变化百分比位于中位数上半区。
临床怎么用
- 关注体外循环时间对心肌水通道蛋白表达及水肿的影响,低心排综合征患者可能水通道蛋白变化更显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Cardiopulmonary bypass (CPB) use is an essential strategy for many cardiovascular surgeries. However, its use and duration have been associated with a higher rate of postoperative complications, such as low cardiac output syndrome due to myocardial oedema and dysfunction. Though Aquaporin water channels have been implicated in myocardial water balance, their specific role in this clinical scenario has not been established. METHODS: In a consecutive study of 17 patients with severe aortic stenosis undergoing aortic valve replacement surgery, 2 myocardial biopsies of the left ventricle were taken: 1 before and 1 after CPB use. Sociodemographic, clinical and laboratory data were collected. Western blot and immunohistochemistry studies were performed. RESULTS: After CPB use, there was a mean increase of ∼62% in Aquaporin 1 protein levels (P = 0.001) and a mean reduction of ∼38% in Aquaporin 4 protein levels (P = 0.030). In immunohistochemistry assays, Aquaporin 1 was found lining small blood vessels, while Aquaporin 4 formed a circular label in cardiomyocytes. There were no changes in the localization of either protein following CPB use. During the observed on-pump time interval, there was a 1.7%/min mean increase in Aquaporin 1 (P = 0.021) and a 2.5%/min mean decrease in Aquaporin 4 (P = 0.018). Myocardial interstitial oedema increased by 42% (95% confidence interval 31-54%) after CPB use. Patients who developed low cardiac output syndrome were in the upper half of the median percentage change of Aquaporin expression. CONCLUSION: Time-dependent changes in cardiac Aquaporin expression may be associated with myocardial oedema and dysfunction related to CPB use.
引用
- Politi MT, Ochoa F, Netti V, et al. Changes in cardiac Aquaporin expression during aortic valve replacement surgery with cardiopulmonary bypass. Eur J Cardiothorac Surg. 2020. PMID: 31535145. doi:10.1093/ejcts/ezz249