文献速递瓣膜外科

二尖瓣生物瓣耐久性:长期随访研究的荟萃分析

Durability of Mitral Valve Bioprostheses: A Meta-Analysis of Long-Term Follow-up Studies.
PubMed 文献 · Ann Thorac Surg · 2019-08-28

1980年后植入且平均年龄相似的患者中,猪瓣组免于结构性瓣膜衰败(SVD)的比例更高,其中Mosaic猪瓣SVD率最低;Mosaic猪瓣与Carpentier心包瓣的长期生存率较高。

要点

  • 二尖瓣生物瓣中,猪瓣组长期免于SVD优于心包瓣组。
  • Mosaic猪瓣在猪瓣中SVD率最低。
  • Mosaic猪瓣与Carpentier心包瓣长期生存率较高。

核心结论

  • 在1980年后接受二尖瓣置换、植入新一代组织瓣且植入时平均年龄相似的手术人群中,长期随访显示猪瓣组免于SVD的比例更高。

研究设计与样本

  • 通过在线数据库进行文献检索,纳入报告二尖瓣置换术后组织瓣衰败且随访超过5年的全文论文。
  • 研究对象为4种猪瓣(Carpentier-Edwards、Hancock、Hancock II、Mosaic)和1种心包瓣(Carpentier-Edwards)。
  • 计算每种假体的年SVD率,并用Kaplan-Meier曲线和log-rank检验比较猪瓣与心包瓣的长期耐久性。

主要发现

  • 猪瓣在引入初期一般植入较年轻的患者。
  • 数十年来,接受二尖瓣生物瓣的患者平均年龄从50岁增至70岁。
  • 在1980年后手术且植入时平均年龄相似的患者中,猪瓣组免于SVD的比例更高,Mosaic猪瓣的SVD率最低。
  • Mosaic猪瓣和Carpentier心包瓣的长期生存率更高。

临床怎么用

  • 对于二尖瓣置换需选用生物瓣的患者,可参考本荟萃分析结果,在猪瓣与心包瓣间权衡长期耐久性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Porcine and pericardial valves exhibited similar freedom from structural valve deterioration after aortic valve replacement. Limited data exist regarding their durability at long-term follow-up in the mitral position. METHODS: A literature search was performed through online databases. Papers reporting freedom from tissue valve deterioration after mitral valve replacement with a follow-up longer than 5 years were retrieved. Four porcine valves (Carpentier-Edwards [Edwards Lifesciences, Irvine, CA] and Hancock, Hancock II, and Mosaic [Medtronic, Inc, Minneapolis, MN]) and 1 pericardial prosthesis (Carpentier-Edwards) were the objects of the study. The structural valve deterioration (SVD) rate per year was calculated for each type of prosthesis. Kaplan-Meier curves and log-rank test analysis were performed to compare the long-term durability of porcine and pericardial valves. RESULTS: Forty full-text papers including more than 15,000 patients were considered for the meta-analysis. Porcine valves were generally implanted in younger patients in the first period after their introduction. The mean age of the patients receiving a mitral bioprosthesis increased from 50 to 70 years over the decades. In patients operated after 1980 who had similar mean age at the time of implant, freedom from SVD was higher in the group of porcine valves with Mosaic prosthesis, showing the lowest rate of SVD. Long-term survival was higher for Mosaic porcine and Carpentier pericardial valves. CONCLUSIONS: In surgical populations that underwent mitral valve replacement after 1980 with new generation tissue valves and similar mean age at the implant time, we found, at long-term follow-up, a higher freedom from SVD in the group of porcine prostheses.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Malvindi PG, Mastro F, Kowalewski M, et al. Durability of Mitral Valve Bioprostheses: A Meta-Analysis of Long-Term Follow-up Studies. Ann Thorac Surg. 2019. PMID: 31472130. doi:10.1016/j.athoracsur.2019.07.024