二十年非体外循环冠状动脉旁路移植术及术后早期血管造影经验
该研究回顾了1998至2017年间2919例接受非体外循环冠状动脉旁路移植术的患者,其中96.6%在术后早期(≤7天)接受了血管造影。结果显示总桥血管通畅率为98.2%,动脉桥高于静脉桥(99.0% vs 96.9%,P < .001)。术中流量测定和基于造影的再干预可能改善桥血管通畅率。
要点
- 非体外循环冠脉搭桥术后早期造影显示总桥血管通畅率98.2%。
- 动脉桥通畅率显著高于静脉桥(99.0% vs 96.9%,P < .001)。
- 基于早期造影的再干预可能改善出院时桥血管通畅率。
核心结论
- 术中流量测定及异常桥血管修正提高了早期动脉桥通畅率。
- 基于早期造影发现的再手术可能进一步改善出院时桥血管通畅率。
研究设计与样本
- 回顾性单中心研究,纳入1998至2017年间2919例接受非体外循环冠状动脉旁路移植术的患者。
- 术后早期(≤7天,平均1.5 ± 1.2天)对2820例(96.6%)患者行血管造影。
主要发现
- 手术死亡率为1.1%(32/2919)。
- 平均远端吻合口数为3.2 ± 1.0。
- 术中流量测定引导下修正远端吻合口失败109/8585(1.3%)。
- 造影显示总通畅率98.2%(8836/9001),动脉桥99.0%(5484/5540),静脉桥96.9%(3352/3461),P < .001。
- 静脉桥中,游离移植通畅率87.2%(231/265),复合移植97.7%(3121/3196),P = .001。
关键数值与推荐
- 引入流量测定后,动脉桥通畅率显著提高(97.2% vs 99.2%,P = .038)。
- 游离静脉桥通畅率无显著改善(86.0% vs 91.4%,P = .181)。
- 基于造影的早期再干预76例(2.7%)。
- 31例接受远端吻合口修正的患者出院前桥血管通畅率从65.1%(56/86)提高至95.3%(82/86),P < .001。
临床怎么用
- 非体外循环冠脉搭桥术中可考虑使用流量测定评估吻合口质量并及时修正异常桥血管。
- 术后早期血管造影有助于发现桥血管失败并指导再干预,可能改善出院时通畅率。
局限性
- 原文未报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We have performed off-pump coronary artery bypass grafting and also performed early postoperative angiography to assess anastomosis accuracy and patency in most of our patients requiring surgical revascularization. METHODS: Of 3083 patients who underwent isolated coronary artery bypass grafting between 1998 and 2017, 2919 patients (94.7%) underwent off-pump coronary artery bypass grafting. Conduits for distal anastomoses were left internal thoracic artery (n = 2764), right internal thoracic artery (n = 866), right gastroepiploic artery (n = 997), radial artery (n = 16), and saphenous vein (n = 1505). Since the introduction of transit-time flow measurement in 2000, we revised abnormal grafts intraoperatively. Early (≤7 days) angiography was performed in 2820 patients (96.6%) at 1.5 ± 1.2 postoperative days, and surgical intervention was performed based on angiographic findings. RESULTS: Operative mortality was 1.1% (32 of 2919). Average number of distal anastomoses was 3.2 ± 1.0. Intraoperative flowmetry-guided revision for distal anastomosis failures was performed in 109 of 8585 distal anastomoses (1.3%). Angiography showed an overall patency of 98.2% (8836 of 9001): 99.0% (5484 of 5540) for arterial and 96.9% (3352 of 3461) for venous conduits (P < .001). Patency of venous conduits was 87.2% (231 of 265) for free grafts and 97.7% (3121 of 3196) for composite grafts (P = .001). After the introduction of transit-time flow measurement, patency of arterial conduits became significantly higher (97.2% vs 99.2%; P = .038); however, patency of free venous conduits was not significantly improved (86.0% vs 91.4%; P = .181). Early re-intervention according to angiographic findings was performed in 76 patients (2.7%). Reevaluation of graft patency before discharge in 31 who underwent revision of distal anastomoses showed improved patency (65.1% [56 of 86] vs 95.3% [82 of 86]; P < .001). CONCLUSIONS: Intraoperative flowmetry and revision of abnormal grafts improved early arterial graft patency, and reoperation based on early angiographic findings may further improve graft patency at the time of discharge.
引用
- Kim KB, Choi JW, Oh SJ, et al. Twenty-Year Experience With Off-Pump Coronary Artery Bypass Grafting and Early Postoperative Angiography. Ann Thorac Surg. 2019. PMID: 31499028. doi:10.1016/j.athoracsur.2019.07.053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。