Y型移植物改良Fontan手术:血流分布随时间趋于均衡
本研究纳入10例使用商用Y型移植物完成Fontan循环的患者,利用连续心脏磁共振数据和计算流体动力学模拟评估肝血流分布与能量损失,并与三组心外管道Fontan患者比较。3年随访时Y型移植物肝血流分布优于心外管道组。
要点
- Y型移植物Fontan术后肝血流分布随时间显著趋于均衡
- 总腔肺连接阻力在Y型移植物随访期间无显著变化
- Y型移植物3年随访肝血流分布优于心外管道组
核心结论
- Y型移植物在3年随访内肝血流分布显著更均衡且总腔肺连接阻力未增加,可能是Fontan完成的有价值选择。
研究设计与样本
- 纳入10例使用商用Y型移植物且有连续术后心脏磁共振数据的Fontan患者,采用患者特异性计算流体动力学模拟评估肝血流分布和能量损失。
- 将Y型移植物性能与3组心外管道Fontan患者(每组n=10)比较,其随访时间跨越Y型移植物的时间点。
主要发现
- 总腔肺连接阻力无显著变化。
- Y型移植物3年随访时肝血流分布比心外管道组在较早和较晚随访时间均更均衡。
- 任何Y型移植物组与心外管道组之间总腔肺连接阻力无显著差异。
临床怎么用
- Y型移植物可作为Fontan完成的一种选择,因其肝血流分布随时间趋于均衡且不增加总腔肺连接阻力。
- 需更长随访数据以充分表征Y型移植物使用的潜在优势。
局限性
- 需要更长时间随访数据以充分描述Y型移植物的潜在优势。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The use of Y-grafts for Fontan completion is hypothesized to offer more balanced hepatic flow distribution (HFD) and decreased energy losses. The purpose of this study was to evaluate the hemodynamic performance of Y-grafts over time using serial cardiac magnetic resonance data and to compare their performance with extracardiac Fontan connections. METHODS: Ten Fontan patients with commercially available Y-graft connections and serial postoperative cardiac magnetic resonance data were included in this study. Patient-specific computational fluid dynamics simulations were used to estimate HFD and energy losses. Y-graft performance was compared with 3 extracardiac conduit Fontan groups (n = 10 for each) whose follow-up times straddle the Y-graft time points. RESULTS: Y-graft HFD became significantly more balanced over time (deviation from 50% decreased from 18% ± 14% to 8% ± 8%; P = .015). Total cavopulmonary connection resistance did not significantly change. Y-grafts at 3-year follow-up showed more balanced HFD than the extracardiac conduit groups at both the earlier and later follow-up times. Total cavopulmonary connection resistance was not significantly different between any Y-graft or extracardiac conduit group. CONCLUSIONS: Y-grafts showed significantly more balanced HFD over a 3-year follow-up without an increase in total cavopulmonary connection resistance, and therefore may be a valuable option for Fontan completion. Additional follow-up data at longer follow-up times are still needed to thoroughly characterize the potential advantages of Y-graft use.
引用
- Trusty PM, Wei Z, Sales M, et al. Y-graft modification to the Fontan procedure: Increasingly balanced flow over time. J Thorac Cardiovasc Surg. 2019. PMID: 31399233. doi:10.1016/j.jtcvs.2019.06.063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。