PubMed 文献 · J Thorac Cardiovasc Surg · 2019-07-10

主要终点为再干预(手术或经导管瓣膜置换),次要终点为瓣膜失败(显著反流或狭窄)。5年和10年免于再干预率分别为95%±4%和83%±8%,免于瓣膜失败率在2年、5年和10年分别为75%±4%、65%±8%和57%±10%。

要点

  • Perimount瓣膜在肺动脉位置5年随访功能良好,但10年后瓣膜失败和再干预常见。
  • 5年和10年免于再干预率分别为95%±4%和83%±8%。
  • 10年免于瓣膜失败率仅57%±10%,取出瓣膜显示纤维化导致瓣叶僵硬。

核心结论

  • Perimount瓣膜在肺动脉位置5年随访功能 adequate,但10年后瓣膜失败和再干预常见,取出瓣膜显示瓣叶因纤维层而回缩和僵硬。

主要发现

  • 共发生7例再干预(5例手术,2例经导管)。
  • 5年和10年免于再干预率分别为95%±4%和83%±8%。
  • 免于瓣膜失败率在2年、5年和10年分别为75%±4%、65%±8%和57%±10%。
  • 形态学评估(n=4)显示瓣膜开放位置僵硬,瓣叶广泛纤维组织增生和不同程度的肌成纤维细胞增殖。

临床怎么用

  • 对于先心病患者肺动脉瓣置换,Perimount瓣膜可作为选择之一,但需告知10年后瓣膜失败和再干预风险较高,应加强远期随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Pulmonary valve replacement is very common among patients with congenital heart disease. The Carpentier Edwards Perimount valve (Edwards Lifesciences, Irvine, Calif), which was originally designed for the aortic position is among the most implanted valves. We aim to describe the follow-up of this valve in the pulmonary position. METHODS: Patients with a Perimount valve implanted between 2003 and 2013 in the University Medical Center Groningen were followed for the primary end point reintervention, defined as surgical or transcatheter valve replacement. Secondary end point was the occurrence of valve failure, defined as significant valvular regurgitation or stenosis. Explanted valves were histologically examined. RESULTS: Forty-five patients (median age at operation 27.8 years, 55.6% women) had a mean follow-up duration of 5.8 ± 3.3 years. There were 7 reinterventions (5 surgical and 2 transcatheter). Freedom from reintervention was respectively 95% ± 4% and 83% ± 8% at 5- and 10- years of follow-up. Freedom from valve failure was 75% ± 4% at 2 years, 65% ± 8% at 5 years of follow-up and 57% ± 10% at 10 years of follow-up. Morphology evaluation (n = 4) showed stiffened valves in the open position, with extensive fibrous tissue overgrowth on the leaflets and a variable proliferation of myofibroblasts. CONCLUSIONS: The Perimount valve has adequate function in the pulmonary valve position at 5 years of follow-up, although after 10 years of follow-up valve failure and reinterventions are common. Explanted valves show retraction and stiffening of the leaflets due to a fibrotic layer on both sides of the leaflet.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Pragt H, Schoots MH, Accord RE, et al. A stented bovine pericardial prosthesis in the pulmonary position. J Thorac Cardiovasc Surg. 2019. PMID: 31400815. doi:10.1016/j.jtcvs.2019.05.086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。