文献速递冠心病外科

主动脉外超声预防冠状动脉旁路移植术后卒中

Epiaortic Ultrasound to Prevent Stroke in Coronary Artery Bypass Grafting.
PubMed 文献 · Ann Thorac Surg · 2019-08-14

基于E-CABG注册研究中7241例孤立性CABG患者,术中行主动脉外超声(EAU)者占9.3%。系统综述与荟萃分析纳入5项研究共11496例患者,EAU组术后卒中 pooled 率显著低于未行EAU组(0.6% vs 1.9%;RR 0.40;95%CI 0.24-0.66;I2=0%)。

要点

  • 避免主动脉操作与CABG后最低卒中风险相关。
  • 计划操作升主动脉时,EAU可指导手术策略以降低栓塞性卒中风险。
  • EAU使用率仅9.3%,推广空间大。

核心结论

  • 避免主动脉操作与CABG患者最低卒中风险相关。
  • 当计划操作升主动脉时,EAU能有效指导手术策略以降低栓塞性卒中风险。

研究设计与样本

  • 基于欧洲多中心冠状动脉旁路移植研究(E-CABG)注册数据的观察性研究,纳入7241例孤立性CABG患者。
  • 另进行系统综述与荟萃分析以佐证观察性研究结果。

主要发现

  • EAU在673/7241例(9.3%)患者中于术中实施。
  • 文献检索纳入5项符合标准的研究,连同本研究共11496例患者,其中3026例(25.7%)行术中EAU。
  • EAU组术后卒中 pooled 率显著低于未行EAU组(0.6% vs 1.9%;风险比0.40;95%CI 0.24-0.66;I2=0%)。

关键数值与推荐

  • 基于 pooled 率,预防1例卒中所需治疗人数(NNT)为76.9。

临床怎么用

  • 在CABG中应优先避免主动脉操作以降低卒中风险。
  • 当计划操作升主动脉时,应使用EAU指导手术策略以减少栓塞性卒中。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Epiaortic ultrasonography (EAU) is a valid imaging method to detect atherosclerotic changes of the ascending aorta and to guide surgical strategies for the prevention of cerebral embolism in patients undergoing isolated coronary artery bypass grafting (CABG). However, its use is not widespread. METHODS: The impact of EAU on the outcome after isolated CABG was investigated in patients from the European Multicenter Study on Coronary Artery Bypass Grafting (E-CABG) registry. A systematic review and meta-analysis of the literature was performed to substantiate the findings of this observational study. RESULTS: EAU was performed intraoperatively in 673 of 7241 patients (9.3%) from the E-CABG registry. In the overall series, the rates of stroke without and with aortic manipulation were 0.3% and 1.3%, respectively (P = .003). In 660 propensity score-matched pairs, EAU was associated with significantly lower risk of stroke (0.6% vs 2.6%, P = .007). A literature search yielded 5 studies fulfilling the inclusion criteria. These studies, along with the present one, included 11,496 patients, of whom 3026 (25.7%) underwent intraoperative EAU. Their rate of postoperative stroke was significantly lower than in patients not investigated with EAU (pooled rate, 0.6% vs 1.9%; risk ratio, 0.40; 95% confidence interval, 0.24-0.66; I2 = 0%). On the basis of these pooled rates, the number needed to treat to prevent 1 stroke is 76.9. CONCLUSIONS: Avoiding aortic manipulation is associated with the lowest risk of stroke in patients undergoing CABG. When manipulation of the ascending aorta is planned, EAU is effective in guiding the surgical strategy to reduce the risk for embolic stroke in these patients.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Biancari F, Santini F, Tauriainen T, et al. Epiaortic Ultrasound to Prevent Stroke in Coronary Artery Bypass Grafting. Ann Thorac Surg. 2019. PMID: 31421104. doi:10.1016/j.athoracsur.2019.06.078

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。