二叶式主动脉瓣患者A型主动脉夹层的临床特征与结局
本研究比较了72例二叶式主动脉瓣(BAV)与1068例三叶式主动脉瓣(TAV)A型主动脉夹层患者的临床、主动脉及结局特征。BAV患者更年轻且心血管危险因素更少,夹层累及腹主动脉更少,主动脉根部置换更常见,但术后结局相似。BAV患者夹层后最大直径及推算夹层前直径均更大,且多数患者夹层前升主动脉直径低于预防性置换阈值。
要点
- BAV患者发生A型夹层时更年轻且心血管危险因素更少。
- BAV患者夹层后最大直径及推算夹层前直径均显著大于TAV患者。
- BAV患者术后结局与TAV患者相似,但近端主动脉修复方式更常涉及根部置换。
核心结论
- BAV患者发生急性A型主动脉夹层不伴有更差的临床或长期结局,但显著影响近端主动脉修复方式。
- 经建模推算,仅不到5%的TAV患者和可能不到25%的BAV患者符合升主动脉预防性置换的选择性阈值。
研究设计与样本
- 回顾性比较研究,纳入2个中心因A型主动脉夹层手术的1068例TAV患者和72例BAV患者。
- 评估并比较患者特征、影像学、手术及结局数据,并按既往报道方法计算夹层前主动脉直径。
主要发现
- BAV患者显著更年轻(P < .001)且心血管危险因素发生率更低。
- TAV患者夹层累及腹主动脉显著更常见(P = .029)。
- BAV患者主动脉根部置换显著更常见(P < .001)。
- 两组术后结局相似。
- BAV患者夹层后最大直径(P < .001)及推算夹层前直径(P < .001)均显著大于TAV患者。
关键数值与推荐
- 夹层前升主动脉直径小于5.5 cm者占全部TAV患者的96%。
- 夹层前升主动脉直径小于5.0 cm者占全部BAV患者的76%。
临床怎么用
- BAV患者A型夹层时更常需根部置换,术前应评估主动脉根部情况。
- BAV患者夹层前升主动脉直径常低于常规预防性置换阈值,现行阈值可能不适用于该人群。
局限性
- 夹层前主动脉直径为推算值而非直接测量。
- 样本中BAV患者数量相对较少(72例)。
- 研究为两中心回顾性设计,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study was to evaluate clinical, aortic, and outcome characteristics of type A aortic dissection patients with bicuspid aortic valves (BAVs) and tricuspid aortic valves (TAVs). METHODS: Patient characteristics and radiographic, operative, and outcome data were evaluated and compared between 1068 TAV patients and 72 BAV patients operated on for type A aortic dissection in 2 centers. Predissection aortic diameters were calculated as previously reported for TAV patients. RESULTS: BAV patients were significantly younger (P < .001) and had a lower incidence of cardiovascular risk factors. Although the clinical presentation was similar, the dissection affected the abdominal aorta significantly more often in TAV patients (P = .029). Aortic root replacements were performed significantly more often in BAV patients (P < .001). Postoperative outcome was similar between the 2 groups. BAV patients had a significantly larger maximum postdissection diameter (P < .001) and calculated predissection diameter (P < .001) compared with TAV patients. Predissection ascending aortic diameters were less than 5.5 cm in 96% of all TAV patients and less than 5.0 cm in 76% of all BAV patients. CONCLUSIONS: Acute type A aortic dissection in BAV patients is not associated with worse clinical or long-term outcome but significantly influences the proximal aortic repair. After modeling predissection aortic diameters, less than 5% of all TAV patients and possibly less than 25% of all BAV patients would meet the elective threshold for preventative replacement of the ascending aorta.
引用
- Kreibich M, Rylski B, Czerny M, et al. Type A Aortic Dissection in Patients With Bicuspid Aortic Valve Aortopathy. Ann Thorac Surg. 2019. PMID: 31265822. doi:10.1016/j.athoracsur.2019.05.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。