右腋动脉入路TAVR应用「翻转-弯曲」技术的早期经验
该研究纳入2016年6月至2018年5月连续10例接受右腋动脉入路经导管主动脉瓣置换术(TAx-TAVR)的患者,使用SAPIEN 3瓣膜及新型「翻转-弯曲」技术。
要点
- 右腋动脉入路TAVR使用SAPIEN 3瓣膜及「翻转-弯曲」技术可行且早期结果满意
- 术后平均跨瓣压差从38.4±12.6 mmHg降至9±4.4 mmHg
- 透视时间从44.1±8.2分钟缩短至17.4±2.9分钟,学习曲线短
核心结论
- 右腋动脉入路TAVR使用SAPIEN 3瓣膜及「翻转-弯曲」技术早期结果满意且学习曲线短。
研究设计与样本
- 单中心回顾性研究,纳入2016年6月至2018年5月连续10例接受右腋动脉入路TAVR的患者。
主要发现
- 10例患者平均年龄81.8±8.7岁,女性占50%,平均STS预测死亡风险12.0%±9.5%。
- 2例(20%)需要植入永久起搏器,术后中位住院时间为4天(范围2-13天)。
- 平均跨瓣压差从38.4±12.6 mmHg降至9±4.4 mmHg,所有患者NYHA心功能分级改善。
- 透视时间从44.1±8.2分钟显著缩短至17.4±2.9分钟。
临床怎么用
- 对于血管迂曲或植入角度不合适的患者,右腋动脉入路TAVR联合「翻转-弯曲」技术可作为备选方案。
局限性
- 样本量小(仅10例),为单中心早期经验,随访时间有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Right transaxillary transcatheter aortic valve replacement (TAx-TAVR) is rarely performed due to challenging vascular tortuosity and unfavorable implantation angles. We explored this procedure using the newer-generation balloon-expandable SAPIEN 3 (Edwards Lifesciences, Irvine, CA) valve and our novel "flip-n-flex" technique. The safety and effectiveness of the procedure and the learning curve of our early experiences were investigated. METHODS: The first 10 consecutive patients undergoing right TAx-TAVR performed at our center from June 2016 to May 2018 were included in the study. Patients' preoperative characteristics, procedural outcomes, and clinical outcomes were studied. Intraoperative fluoroscopy times were also reviewed to analyze the procedural learning curve. RESULTS: The 10 patients were a mean age of 81.8 ± 8.7 years, and 5 patients (50%) were women. Mean Society of Thoracic Surgeons Predicted Risk of Mortality was 12.0% ± 9.5%. Procedural success was achieved in all cases without vascular complications. Paravalvular leak was absent or mild in all patients. Two patients (20%) required permanent pacemaker implantation. The median postoperative length of stay was 4 days (range, 2-13 days). The 30-day mortality was 0%. Mean transvalvular gradient improved from 38.4 ± 12.6 mm Hg to 9 ± 4.4 mm Hg postoperatively. New York Heart Association Functional Classification improved in all patients. The fluoroscopy time showed marked reduction from 44.1 ± 8.2 minutes to 17.4 ± 2.9 minutes with the use of the flip-n-flex technique. CONCLUSIONS: Our early experience of right TAx-TAVR with the SAPIEN 3 valve demonstrated satisfactory outcomes and a quick learning as facilitated by the flip-n-flex technique. This could be a beneficial TAVR approach to suitable patients.
引用
- Zhan Y, Kawabori M, Lofftus S, et al. Right Transaxillary Transcatheter Aortic Valve Replacement Using the "Flip-n-Flex" Technique. Ann Thorac Surg. 2019. PMID: 31279789. doi:10.1016/j.athoracsur.2019.05.040