文献速递冠心病外科

非体外循环冠脉搭桥术后早期静脉桥失败预测因素:233例血管CT结果

Predictors of early vein graft failure after off-pump coronary artery bypass grafting: angiocomputed tomographic results of 233 patients.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

本研究对233例接受非体外循环冠状动脉旁路移植术(OPCAB)的患者术后行冠状动脉CT血管造影,评估早期静脉桥失败(VGF)的预测因素。术后1周大隐静脉桥FitzGibbon-A通畅率为94.1%(659/700)。患者水平预测因素包括术前血小板计数升高、围术期红细胞输注量增加和肌酐清除率升高,左乳内动脉桥为保护因素;桥血管水平预测因素包括术前血小板计数升高、肌酐清除率升高、围术期红细胞输注量增加和内膜剥脱,而双联抗血小板治疗、较大受体血管直径、较大桥血管流出量、较高术前红细胞计数和侧侧吻合为保护因素。

要点

  • OPCAB术后1周大隐静脉桥FitzGibbon-A通畅率为94.1%(659/700)。
  • 患者水平VGF预测因素:术前血小板计数升高、围术期红细胞输注量增加、肌酐清除率升高;左乳内动脉桥为保护因素。
  • 桥血管水平保护因素包括双联抗血小板治疗、受体血管直径较大、桥血管流出量较大、术前红细胞计数较高和侧侧吻合。

核心结论

  • OPCAB术后早期大隐静脉桥通畅率满意,术前血小板计数升高、围术期红细胞输注量增加和肌酐清除率升高是患者水平早期VGF的预测因素,左乳内动脉桥为保护因素。
  • 桥血管水平早期VGF预测因素包括术前血小板计数升高、肌酐清除率升高、围术期红细胞输注量增加和内膜剥脱,保护因素包括双联抗血小板治疗、较大受体血管直径、较大桥血管流出量、较高术前红细胞计数和侧侧吻合。

研究设计与样本

  • 对233例接受OPCAB的患者术后行冠状动脉CT血管造影评估桥血管通畅性,并在患者水平和桥血管水平进行Logistic回归分析以检测早期VGF(FitzGibbon-B/O)的预测因素。

主要发现

  • 术后1周大隐静脉桥FitzGibbon-A通畅率为94.1%(659/700)。
  • 患者水平:术前血小板计数升高(OR 9.848)、围术期红细胞输注量增加(U,OR 1.544)和肌酐清除率升高(ml/min,OR 1.037)是早期VGF预测因素,左乳内动脉桥为保护因素(OR 0.348)。
  • 桥血管水平:术前血小板计数升高(OR 17.450)、肌酐清除率升高(ml/min,OR 1.034)、围术期红细胞输注量增加(U,OR 1.505)和内膜剥脱(OR 5.499)是早期VGF预测因素。
  • 桥血管水平保护因素:双联抗血小板治疗(OR 0.419)、受体血管直径(mm,OR 0.052)、桥血管流出量(ml/min,OR 0.949)、术前红细胞计数(×1012,OR 0.576)和侧侧吻合(与端侧吻合相比,OR 0.276)。
  • 吻合至直径>1.5 mm血管的静脉桥通畅率显著高于其他(96.6% vs 91.1%),桥血管流出量>25 ml/min每吻合口的静脉桥通畅率显著高于其他(95.1% vs 88.7%)。

关键数值与推荐

  • 受体血管直径>1.5 mm和桥血管流出量>25 ml/min为检测VGF的截断值。

临床怎么用

  • 对于术前血小板计数升高、肌酐清除率升高或围术期需大量红细胞输注的患者,应加强术后静脉桥失败的监测。
  • 术中优先选择左乳内动脉桥、较大受体血管直径(>1.5 mm)、较大桥血管流出量(>25 ml/min每吻合口)和侧侧吻合,并考虑双联抗血小板治疗以降低早期VGF风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Low saphenous vein graft (SVG) patency has become the bottleneck in surgical revascularization. This study aimed to identify the predictors of early vein graft failure (VGF) after off-pump coronary bypass grafting (OPCAB). METHODS: A total of 233 patients who had OPCAB were postoperatively evaluated by coronary computed tomography angiography. Logistic regression analyses were performed to detect the predictors of early VGF (FitzGibbon-B/O) at both the patient and the graft level. RESULTS: Overall FitzGibbon-A patency of SVG at 1 week after OPCAB was 94.1% (659/700). At the patient level, a patient who had at least 1 VGF was regarded as an event, and increased preoperative platelet count [odds ratio (OR) 9.848], quantity of perioperatively transfused red blood cells (RBC) (U, OR 1.544) and creatinine clearance rate (CCr) (ml/min, OR 1.037) were predictors of early VGF, whereas use of a left internal mammary artery graft was a protective factor (OR 0.348). At the graft level, when VGF was regarded as an event, increased preoperative platelet count (OR 17.450), CCr (ml/min, OR 1.034), quantity of perioperatively transfused RBC (U, OR 1.505) and endarterectomy (OR 5.499) were predictors of early VGF. Under the same circumstances, dual antiplatelet therapy (OR 0.419), recipient vessel diameter (mm, OR 0.052), graft run-off (ml/min, OR 0.949), preoperative RBC count (×1012, OR 0.576) and a side-to-side (when compared with end-to-side) anastomosis (OR 0.276) were protective factors. The patency of SVGs sutured to vessels with a larger diameter (>1.5 mm) was significantly higher than that of the others (96.6% vs 91.1%). SVGs with greater run-off (>25 ml/min for each anastomosis) were significantly more patent than others (95.1% vs 88.7%). CONCLUSIONS: Early SVG patency after OPCAB was satisfactory. Increased preoperative platelet count, more perioperative RBC transfusions and higher CCr were predictors of patients with early VGF, whereas use of a left internal mammary artery graft was a protective factor. Increased preoperative platelet count, higher CCr, more perioperative RBC transfusions and endarterectomy were predictors of VGF, whereas dual antiplatelet therapy, larger recipient vessel diameter, greater graft run-off, higher preoperative RBC count and side-to-side anastomosis were protective factors. Recipient diameter >1.5 mm and graft run-off >25 ml/min were cut-off values for detecting VGF.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Yang Y, Zhu Y, Tang C, et al. Predictors of early vein graft failure after off-pump coronary artery bypass grafting: angiocomputed tomographic results of 233 patients. Eur J Cardiothorac Surg. 2020. PMID: 31302683. doi:10.1093/ejcts/ezz207

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。