低温循环停搏下胸腹主动脉瘤修复的早期结局
该研究回顾性分析了30年间285例采用体外循环联合低温循环停搏行胸腹主动脉瘤修复的患者,其中Crawford I型72例、II型107例、III型104例、IV型2例。30天死亡率为7.4%,永久性截瘫发生率为5.3%,1年实际生存率为90.4%。结论认为该技术安全有效,脊髓损伤和永久性肾衰竭发生率处于文献报道的较低水平。
要点
- 30天死亡率为7.4%,Crawford II型和III型最高,分别为10.3%和6.7%。
- 永久性截瘫发生率为5.3%,II型和III型分别为6.5%和6.7%。
- 脑脊液引流对脊髓损伤无影响,肋间/腰动脉植入仅在II型修复中有保护作用。
核心结论
- 长期经验证实该技术常规应用安全有效,脊髓损伤和永久性肾衰竭发生率处于文献报道的较低水平。
- 年轻患者和择期手术患者 outcomes 尤其良好。
研究设计与样本
- 回顾性单中心研究,30年间共285例胸腹主动脉瘤修复患者,均采用体外循环联合低温循环停搏。
- 动脉瘤分型:Crawford I型72例,II型107例,III型104例,IV型2例。
- 病因:退行性动脉瘤占72.6%,主动脉夹层占26.4%;因破裂或急性夹层急诊手术占6.7%。
主要发现
- 30天死亡率为7.4%,Crawford II型和III型分别为10.3%和6.7%。
- 永久性截瘫发生率为5.3%,II型和III型分别为6.5%和6.7%。
- 脑脊液引流对脊髓损伤发生无影响,肋间/腰动脉植入仅在II型修复患者中有保护作用。
- 卒中发生率为4.2%,需透析的肾衰竭发生率为6.2%。
- 1年实际生存率为90.4%。
临床怎么用
- 对于胸腹主动脉瘤开放手术,体外循环联合低温循环停搏可作为常规器官保护策略。
- Crawford II型和III型患者死亡和截瘫风险较高,应加强围术期管理。
- 肋间/腰动脉植入在II型修复中可能具有保护作用,脑脊液引流未显示获益。
局限性
- 回顾性单中心研究,缺乏对照组,结论推广需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A variety of intraoperative strategies are currently used for organ protection during open operations on the thoracoabdominal aorta. We report our experience with cardiopulmonary bypass and hypothermic circulatory arrest as the primary modality for organ protection, focusing on the early outcomes. METHODS: During a 30-year interval, 285 patients underwent thoracoabdominal aortic aneurysm repair with the use of cardiopulmonary bypass with an interval of circulatory arrest (72 Crawford extent I, 107 extent II, 104 extent III, and 2 extent IV). Degenerative aneurysms were present in 72.6% and aortic dissections in 26.4% of patients. Emergent operations for rupture or acute dissection were required in 6.7% of the patients. RESULTS: Thirty-day mortality was 7.4% and was highest for the Crawford extent II and extent III patients (10.3% and 6.7%, respectively). Permanent paralysis or paraplegia occurred in 15 patients (5.3%). The rates were highest for the extent II and extent III patients (6.5% and 6.7%, respectively). Cerebrospinal fluid drainage had no impact on the development of spinal cord injury, and implantation of intercostal/lumbar arteries had a protective effect only in patients with extent II repair. Stroke occurred in 4.2% of patients and renal failure that required dialysis occurred in 6.2%. One-year actual survival was 90.4%. CONCLUSIONS: Our extended experience with this technique confirms its safety and effectiveness when used on a routine basis. The rates of spinal cord injury and permanent renal failure are among the lowest reported in the literature. Particularly favorable outcomes were observed in younger patients and patients undergoing elective operations.
引用
- Kouchoukos NT, Kulik A, Haynes M, et al. Early Outcomes After Thoracoabdominal Aortic Aneurysm Repair With Hypothermic Circulatory Arrest. Ann Thorac Surg. 2019. PMID: 31085168. doi:10.1016/j.athoracsur.2019.04.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。