文献速递冠心病外科瓣膜外科主动脉外科

心脏手术中右心室功能下降与手术特征及心包切开无关

Right ventricular function is reduced during cardiac surgery independent of procedural characteristics, reoperative status, or pericardiotomy.
PubMed 文献 · J Thorac Cardiovasc Surg · 2019-04-26

该前瞻性研究对109例接受冠脉搭桥、瓣膜或主动脉手术的患者进行标准化经食管超声心动图检查,发现体外循环后右心室长轴及整体功能显著降低,而心包切开后未见显著变化。功能降低在胸骨切开、微创切口及再次手术中均一致存在,且持续至关胸后。

要点

  • 体外循环后右心室功能显著下降,心包切开后无显著变化。
  • 右心室功能降低在不同手术类型、切口及再次手术中一致。
  • 关胸后右心室功能降低持续存在。

核心结论

  • 体外循环后出现急性右心室功能降低,与手术特征及心包切开无关。

研究设计与样本

  • 前瞻性研究,纳入109例接受冠脉搭桥、二尖瓣或主动脉瓣手术和/或主动脉手术的患者。
  • 通过胸骨正中切开、微创胸骨切开或右胸切口入路,于麻醉诱导后、心包切开后、体外循环后及关胸后4个时间点行标准化经食管超声心动图检查。

主要发现

  • 体外循环后与基线相比,三尖瓣环收缩期位移(TAPSE)为1.5(1.1, 1.7)mm vs 2.2(1.8, 2.5)mm,右心室应变-16(-20, -14)% vs -22(-24, -18)%,面积变化分数(FAC)42(34, 49)% vs 45(35, 51)%。
  • 心包切开后右心室功能测量值较基线无显著降低。
  • 关胸后右心室功能降低持续存在:TAPSE 1.3(1.0, 1.6)mm,右心室应变-16(-18, -13)%,FAC 38(31, 46)%。
  • 右心室功能降低见于各类心脏手术、不同手术入路及初次与再次手术。

临床怎么用

  • 心脏手术围术期应关注体外循环后右心室功能的急性降低,尤其关胸后仍持续存在。

局限性

  • 右心室功能降低的病因及临床意义尚未确定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Long-axis right ventricular (RV) function, which provides nearly 80% of RV ejection, acutely decreases during cardiac surgery. RV dysfunction increases risk for perioperative morbidity and mortality. Our objective was to characterize the change in perioperative RV long-axis and global function by determining the influence of procedure type, surgical approach, and reoperative status and examining its temporal relationship to pericardiotomy versus cardiopulmonary bypass (CPB) and cardioplegia. METHODS: Standardized transesophageal echocardiographic examinations (TEEs) were prospectively performed in 109 patients undergoing coronary artery bypass grafting, mitral or aortic valve surgery, and/or aortic surgery via full sternotomy, mini-sternotomy, or right thoracotomy. Mid-esophageal, 4-chamber views centered on the RV were recorded at 4 intraoperative time points, following: (1) anesthetic induction; (2) pericardiotomy; (3) CPB; and (4) chest closure. Long-axis RV function was assessed by tricuspid annular plane systolic excursion and 2-dimensional longitudinal RV strain, and global RV function by fractional area change (FAC), calculated off-line from 2-dimensional TEE images. RESULTS: TEE measures of RV function were significantly reduced after CPB compared with baseline (baseline vs after CPB: TAPSE 2.2 [Q1, Q3: 1.8, 2.5] vs 1.5 [1.1, 1.7] mm; RV strain -22 [-24, -18] vs -16 [-20, -14] %; FAC 45 [35, 51] vs 42 [34, 49] %), but not after pericardiotomy. Reduced RV function persisted after chest closure: tricuspid annular plane systolic excursion 1.3 [1.0, 1.6] mm, RV strain -16 [-18, -13]%, FAC 38 [31, 46] %. Reduced function was demonstrated across cardiac surgical procedures, approaches, and primary and reoperative surgery. CONCLUSIONS: Acute intraoperative reduction in RV function occurs following CPB, independent of procedural characteristics and pericardiotomy. Etiology and clinical implications of reduced perioperative RV function remain to be determined.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Singh A, Huang X, Dai L, et al. Right ventricular function is reduced during cardiac surgery independent of procedural characteristics, reoperative status, or pericardiotomy. J Thorac Cardiovasc Surg. 2019. PMID: 31133354. doi:10.1016/j.jtcvs.2019.04.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。