文献速递冠心病外科

非体外循环冠脉搭桥术后早期无声桥血管失败的CT分析

Early silent graft failure in off-pump coronary artery bypass grafting: a computed tomography analysis†.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-01-01

本研究回顾性分析192例非体外循环冠脉搭桥术后无症状患者第7±4天的CT扫描,评估早期无声桥血管失败的预测因素。共评估359条动脉和278条静脉吻合口,33例患者存在至少1条闭塞吻合口,静脉桥通畅率88.9%,动脉桥96.4%。低流量和高搏动指数与桥血管闭塞显著相关,计算截止值为流量<23 ml/min和搏动指数>2.3。

要点

  • 静脉桥早期无声失败率高于动脉桥,女性更易发生。
  • 低流量和高搏动指数是桥血管闭塞的显著预测因素。
  • 流量<23 ml/min和搏动指数>2.3时闭塞概率增加。

核心结论

  • 早期无声桥血管失败主要发生于静脉桥,女性有倾向性。
  • 低流量和高搏动指数与桥血管闭塞显著相关。
  • 侧支循环和自体血管狭窄程度似乎作用有限。

研究设计与样本

  • 回顾性分析2017年1月至2018年4月192例连续无症状患者的CT扫描(术后第7±4天)。
  • 共评估359条动脉和278条静脉吻合口,比较总体通畅组与至少1条闭塞吻合口组。

主要发现

  • 33例患者发现至少1条闭塞吻合口,女性更常见(P=0.04)。
  • 动脉吻合口通畅率96.4%,静脉吻合口通畅率88.9%。
  • 闭塞组旁路流量较低(P=0.02,OR 3.2,95%CI 1.7-6.0),搏动指数较高(P<0.001,OR 4.5,95%CI 2.4-8.5)。
  • 计算截止值:流量<23 ml/min和搏动指数>2.3时桥血管闭塞概率增加。
  • 14例闭塞吻合口患者在出院前成功接受介入血运重建。

关键数值与推荐

  • 动脉吻合口通畅率96.4%,静脉吻合口通畅率88.9%。
  • 流量<23 ml/min和搏动指数>2.3提示桥血管闭塞概率增加。

临床怎么用

  • 术后CT可早期发现无症状桥血管失败,尤其静脉桥和女性患者。
  • 术中流量测量低流量和高搏动指数应警惕桥血管闭塞风险。
  • 发现闭塞后可考虑出院前介入血运重建。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The purpose was to assess predictors of early silent graft failure prior to discharge by multislice computed tomography in patients after off-pump coronary artery bypass grafting. METHODS: From January 2017 until April 2018, 192 computed tomographic scans of consecutive asymptomatic patients were performed (seventh postoperative day ± 4 days) and analysed retrospectively. In total, 359 arterial and 278 venous anastomoses were evaluated. Two patient groups (overall patent anastomoses versus at least 1 occluded anastomosis) were compared. Cardiovascular risk factors, collateralization according to Rentrop, grade of native vessel stenosis and intraoperative flow measurements were analysed. Inferential statistics were performed with the Mann-Whitney U-test. Nominal and categorical variables were tested with the Fisher-Freeman-Halton exact test. RESULTS: In 33 patients, at least 1 occluded anastomosis could be identified, predominantly in women (P = 0.04). The patency of the arterial anastomoses was 96.4% and 88.9% for the venous anastomoses. In 14 patients with occluded anastomoses, a successful interventional revascularization was performed before discharge. There were significant differences in lower bypass flow [P = 0.02, odds ratio 3.2, 95% confidence interval (CI) 1.7-6.0] and higher pulsatility index (P < 0.001, odds ratio 4.5, 95% CI 2.4-8.5) in the occluded group. A calculated cut-off value identified an increased probability for graft occlusion at a flow under 23 ml/min and a pulsatility index greater than 2.3. CONCLUSIONS: Early silent graft failure occurred predominantly in venous grafts, with a tendency to female gender. A lower flow rate and a higher pulsatility index were significantly associated with graft occlusion, whereas collateralization and the degree of native vessel stenosis seem to play a tangential role. Fourteen patients had a successful percutaneous revascularization before discharge. CLINICAL TRIAL REGISTRATION NUMBER: NCT03657199.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Zientara A, Rings L, Bruijnen H, et al. Early silent graft failure in off-pump coronary artery bypass grafting: a computed tomography analysis†. Eur J Cardiothorac Surg. 2019. PMID: 31006005. doi:10.1093/ejcts/ezz112

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。