两种冷冻象鼻支架治疗急性主动脉夹层的多中心经验
该多中心回顾性研究纳入2005年8月至2018年3月88例因急性主动脉夹层行冷冻象鼻支架手术的患者,比较Thoraflex™ hybrid(55例)与E-vita Open(33例)的早中期结局及主动脉重塑。两组院内死亡率、卒中及脊髓损伤无显著差异,但Thoraflex组二次主动脉腔内干预率显著更高(22% vs 0%;P=0.003)。
要点
- 两种冷冻象鼻支架的院内死亡率、卒中和脊髓损伤无显著差异
- Thoraflex组二次主动脉腔内干预率显著高于E-vita Open组
- E-vita Open组支架段假腔血栓形成率有更高趋势(74% vs 95%;P=0.085)
核心结论
- 两种冷冻象鼻支架手术技术对院内结局无显著影响,但E-vita Open组1年随访时二次主动脉干预率显著更低且假腔血栓形成率有更高趋势。
研究设计与样本
- 多中心回顾性研究,纳入2005年8月至2018年3月连续88例因急性主动脉夹层行冷冻象鼻支架手术的患者,Thoraflex™ hybrid组55例,E-vita Open组33例。
主要发现
- 两组院内死亡率分别为11%与12%(P>0.99),卒中为18%与6%(P=0.12),脊髓损伤均为6%(P>0.99)。
- 远端支架诱导新发破口发生率分别为16%与18%(P=0.77),无显著差异。
- 二次主动脉腔内干预率分别为22%与0%(P=0.003),Thoraflex组显著更高。
- 支架段假腔血栓形成率分别为74%与95%(P=0.085),胸腹交界处分别为53%与80%(P=0.36),均无显著差异但支架段有趋势。
临床怎么用
- 急性主动脉夹层行冷冻象鼻支架手术时,两种支架均可选择,但需注意Thoraflex组二次主动脉干预率较高。
- E-vita Open因支架更长且更多植入于3区,可能有利于假腔血栓形成并减少二次干预。
局限性
- 原文未明确报告局限性内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex™ hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection. METHODS: All consecutive patients [n = 88; median age 59 (49-67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex™ device was implanted in 55 patients and the E-vita Open graft in 33 patients. RESULTS: Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex™ hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses. CONCLUSIONS: In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.
引用
- Berger T, Weiss G, Voetsch A, et al. Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection†. Eur J Cardiothorac Surg. 2019. PMID: 30844055. doi:10.1093/ejcts/ezz037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。