文献速递主动脉外科

估算急性A型主动脉夹层撕前升主动脉直径的方程

Equations Estimating the Predissected Diameter of the Ascending Aorta for Acute Type A Aortic Dissection.
PubMed 文献 · Ann Thorac Surg · 2019-03-23

本研究基于28例急性A型主动脉夹层患者夹层前3年内CT影像,开发新方程以估算撕前升主动脉及主动脉弓直径。四种参数方程偏差与准确性相近(<9.42 mm),简化修正方程y=0.9x(基于post-wCL)偏差5.5±4.9 mm、准确性84.6%,在post-tCL/post-wCL≥0.66时改善至4.4±3.3 mm和93.4%。

要点

  • 新方程可估算急性A型夹层撕前升主动脉及主动脉弓直径。
  • 简化修正方程y=0.9x基于夹层后全周长,便于临床使用。
  • post-tCL/post-wCL≥0.66时方程准确性提高至93.4%。

核心结论

  • 新开发的方程可用于计算急性A型主动脉夹层患者的撕前升主动脉直径和主动脉弓直径。

研究设计与样本

  • 从684例A型主动脉夹层患者中匹配28例,使用夹层前3年内CT图像测量参数并推导方程。

主要发现

  • 四种方程(post-wCL、post-Dma、[post-tCL+post-wCL]/2、[post-Dma+post-Dmi]/2)偏差和准确性相近(<9.42 mm)。
  • 简化修正方程y=0.9x(基于post-wCL)偏差5.5±4.9 mm,准确性84.6%。
  • post-tCL/post-wCL≥0.66时,偏差改善至4.4±3.3 mm,准确性93.4%。

关键数值与推荐

  • 修正方程y=0.9x基于post-wCL,偏差5.5±4.9 mm,准确性84.6%。
  • post-tCL/post-wCL≥0.66时,偏差4.4±3.3 mm,准确性93.4%。

临床怎么用

  • 可用于急性A型主动脉夹层腔内治疗时基于撕前直径选择支架移植物尺寸。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A successful endovascular treatment for acute type A dissection has been recently reported. However, there has been no consensus regarding the appropriate stent graft size based on the estimated predissected aortic diameter for this pathology. METHODS: We developed new equations for estimating the predissected ascending aorta and aortic arch by investigating computed tomography images that had been scanned less than 3 years before dissection. From 684 patients with type A AAD, 28 were matched for the study. We measured the predissected whole circumference length (pre-wCL), postdissected whole circumference length (post-wCL), postdissected true lumen circumference length (post-tCL), postdissected major diameter (post-Dma), and postdissected minor diameter (post-Dmi) of the acutely dissected aorta. This was followed by the calculation of (post-tCL + post-wCL)/2 and (post-Dma + post-Dmi)/2. Six equations (linear function) and modified equations were derived from each of the abovementioned parameters. RESULTS: Four equations (post-wCL, post-Dma, [post-tCL + post-wCL]/2, and [post-Dma + post-Dmi]/2) had nearly the same bias and accuracy (<9.42 mm). For clinical use, we also developed one modified equation using the post-wCL (y = 0.9x) among four parameters because of its simplicity and decreased the possibility of measurement error. The biases of circumference length and accuracy were 5.5 ± 4.9 mm and 84.6%, respectively, and they improved to 4.4 ± 3.3 mm and 93.4% in cases with a ratio of post-tCL/post-wCL of 0.66 or more. CONCLUSIONS: Our newly developed equation can be used to calculate the predissected ascending aortic diameter and aortic arch diameter in cases of acute type A dissection.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Yamauchi T, Takano H, Takahashi T, et al. Equations Estimating the Predissected Diameter of the Ascending Aorta for Acute Type A Aortic Dissection. Ann Thorac Surg. 2019. PMID: 30914284. doi:10.1016/j.athoracsur.2019.02.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。