文献速递瓣膜外科

小号组织瓣与机械主动脉瓣膜性能的荟萃分析

A meta-analysis of the performance of small tissue versus mechanical aortic valve prostheses.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-01-01

该荟萃分析比较小主动脉根患者接受组织瓣与机械瓣的结局,共纳入5项研究680例患者(组织瓣227例,机械瓣453例)。随访死亡率无组间差异,但组织瓣组患者-瓣膜不匹配率更高且左室质量回归更少,提示小号组织瓣患者可能需要更密切的临床监测。

要点

  • 小号组织瓣与机械瓣随访死亡率无显著差异(IRR 1,95%CI 0.50-2.01,P=0.99)。
  • 组织瓣组患者-瓣膜不匹配率显著高于机械瓣组(OR 17.19,95%CI 8.6-25.78,P=0.002)。
  • 组织瓣组左室质量回归显著少于机械瓣组(WMD 40.79,95%CI 4.62-76.96,P=0.02)。

核心结论

  • 小号组织瓣与机械瓣随访死亡率相似,但组织瓣组患者-瓣膜不匹配率更高且左室质量回归更少。
  • 接受小号组织瓣的患者可能需要比机械瓣患者更密切的临床监测。

研究设计与样本

  • 系统文献综述识别7项候选研究,其中5项符合荟萃分析标准。
  • 共分析680例患者,组织瓣227例,机械瓣453例,采用随机效应模型。
  • 每项研究均评估异质性和质量。

主要发现

  • 随访死亡率无组间差异(发生率比1,95%CI 0.50-2.01,P=0.99)。
  • 组织瓣组患者-瓣膜不匹配率更高(OR 17.19,95%CI 8.6-25.78,P=0.002)。
  • 组织瓣组左室质量减少显著更少(WMD 40.79,95%CI 4.62-76.96,P=0.02)。
  • 随访时结构性瓣膜病发生率与机械瓣组相比无显著差异。
  • 随访时汇总不良事件无组间差异(P=0.68)。

临床怎么用

  • 小主动脉根患者选择组织瓣时,应警惕患者-瓣膜不匹配风险更高且左室质量回归更少。
  • 接受小号组织瓣的患者可能需要更密切的临床监测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Small aortic prosthetic valves have been associated with suboptimal performance due to patient-prosthesis mismatch (PPM). This meta-analysis compared the outcomes of patients with a small root who received tissue versus mechanical aortic valves. METHODS: A systematic literature review identified 7 candidate studies; of these, 5 met the meta-analysis criteria. We analysed outcomes for a total of 680 patients (227 tissue valves and 453 mechanical valves) using random effects modelling. Each study was assessed for heterogeneity and quality. The primary end point was mortality at follow-up. Secondary end points included intraoperative and postoperative outcomes, the rate of PPM and left ventricle mass regression and major cardiac and prosthesis-related adverse events at follow-up. RESULTS: There was no between-group difference in mortality at follow-up [incidence rate ratio 1, 95% confidence interval (CI) 0.50-2.01; P = 0.99]. The tissue group had a higher rate of PPM (odds ratio 17.19, 95% CI 8.6-25.78; P = 0.002) and significantly less reduction in ventricular mass (weighted mean difference 40.79, 95% CI 4.62-76.96; P = 0.02). There were no significant differences in the incidence of structural valve disease at follow-up compared to that in the mechanical valve group. There was also no between-group difference in aggregated adverse events at follow-up (P = 0.68). CONCLUSIONS: Tissue and mechanical valves were associated with similar mortality rates; however, patients receiving tissue valves had a higher rate of PPM and significantly less left ventricle mass regression. These findings indicate that patients receiving small tissue valves may require closer clinical surveillance than those receiving mechanical valves.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Moscarelli M, Fattouch K, Speziale G, et al. A meta-analysis of the performance of small tissue versus mechanical aortic valve prostheses. Eur J Cardiothorac Surg. 2019. PMID: 30815676. doi:10.1093/ejcts/ezz056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。