微创主动脉瓣置换术中使用免缝合快速释放瓣膜:国际注册研究报告
该研究基于SURD-IR注册数据库,分析2009至2018年间1418例(占73.3%)接受微创主动脉瓣置换术的免缝合快速释放瓣膜患者。结果显示总体院内死亡率为1.7%、卒中率为2%,永久起搏器植入率为9%且随时间显著下降;Perceval瓣膜手术时间更短,Intuity瓣膜血流动力学更优。
要点
- 微创免缝合快速释放主动脉瓣置换术院内死亡率1.7%、卒中率2%。
- 永久起搏器植入率9%,观察期内从20.6%降至5.6%(P=0.002)。
- Perceval瓣膜手术时间更短,Intuity瓣膜术后血流动力学更优。
核心结论
- 在SURD-IR队列中,使用Perceval和Intuity瓣膜的微创免缝合快速释放主动脉瓣置换术安全可行、早期结果良好。
研究设计与样本
- 基于Sutureless and Rapid Deployment International Registry(SURD-IR)的多中心注册研究,纳入2009至2018年间1418例(73.3%)接受微创初次孤立免缝合快速释放主动脉瓣置换术的患者。
主要发现
- 总体院内死亡率为1.7%,卒中率为2%。
- 永久起搏器植入率为9%,观察期内从20.6%显著降至5.6%(P=0.002)。
- Perceval瓣膜与更短的手术时间相关,且更常用于右前胸小切口入路。
- Intuity瓣膜更常用于年轻患者,并显示出更优的术后血流动力学结果。
关键数值与推荐
- 微创入路包括上半胸骨小切口56.4%(n=800)和右前胸小切口43.6%(n=618)。
- Perceval S植入1011例(71.3%),Edwards Intuity或Intuity Elite植入407例(28.7%)。
临床怎么用
- 微创免缝合快速释放主动脉瓣置换术可作为微创手术的主要适应证,Perceval和Intuity瓣膜均可安全使用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The impact of sutureless and rapid deployment (SURD) valves on the clinical outcomes of patients undergoing minimally invasive aortic valve replacement (MI-AVR) has still to be defined. The aim of this study was to assess clinical characteristics and in-hospital results of patients receiving SURD-AVR through less invasive approaches in the large population of the Sutureless and Rapid Deployment International Registry (SURD-IR). METHODS: Of the 1935 patients who received primary isolated SURD-AVR between 2009 and 2018, a total of 1418 (73.3%) underwent MI interventions and were included in this analysis. SURD-AVR was performed using upper ministernotomy in 56.4% (n = 800) of cases and anterior right thoracotomy in 43.6% (n = 618). Perceval S was implanted in 1011 (71.3%) patients and Edwards Intuity or Intuity Elite in 407 (28.7%) patients. RESULTS: Overall in-hospital mortality and stroke rates were 1.7% and 2%, respectively. A definitive pacemaker implantation was reported in 9% of cases and significantly decreased over the observational period, from 20.6% to 5.6% (P = 0.002). The Perceval valve was associated with shorter operative times and was more frequently implanted in patients receiving anterior right thoracotomy incision. The Intuity valve was preferred in younger patients and revealed superior postoperative haemodynamic results. CONCLUSIONS: SURD-AVR was largely performed through less invasive approaches and can be considered as a primary indication in MI surgery. In the SURD-IR cohort, MI SURD-AVR using both Perceval and Intuity valves appeared a safe and reproducible procedure associated with promising early results.
引用
- Berretta P, Andreas M, Carrel TP, et al. Minimally invasive aortic valve replacement with sutureless and rapid deployment valves: a report from an international registry (Sutureless and Rapid Deployment International Registry)†. Eur J Cardiothorac Surg. 2019. PMID: 30820549. doi:10.1093/ejcts/ezz055
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。