文献速递瓣膜外科

退行性二尖瓣反流瓣环成形术中的患者-人工瓣膜不匹配:一个被忽视的问题

Patient-prosthesis mismatch in mitral annuloplasty for degenerative mitral regurgitation: an ignored issue.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-01-01

该回顾性研究纳入2006至2017年262例因退行性病变行二尖瓣修复的患者,探讨瓣环成形环尺寸与术后二尖瓣跨瓣压差及晚期房颤的关系。研究发现以POAi≤2.28 cm²/m²定义患者-人工瓣膜不匹配(PPM),PPM发生率为43.1%,倾向评分匹配后PPM组5年晚期房颤率显著高于非PPM组(24% vs 5%,P<0.001)。

要点

  • 瓣环成形术后跨瓣压差随POAi减小呈指数性升高。
  • 以晚期房颤为终点,PPM定义为POAi≤2.28 cm²/m²(c-statistic 0.71)。
  • 选择成形环尺寸时应结合体表面积,以减少PPM相关房颤。

核心结论

  • 全环瓣环成形术中,POAi较小时术后跨瓣压差显著升高。
  • PPM患者晚期房颤发生率显著高于非PPM患者。
  • 选择合适成形环尺寸需同时考虑患者体表面积与瓣膜尺寸。

研究设计与样本

  • 回顾性研究,纳入2006至2017年262例因退行性病变行二尖瓣修复的患者。
  • 采用回归曲线和受试者工作特征曲线分析POAi与术后跨瓣压差及晚期房颤的关系。
  • 以预测晚期房颤的最佳POAi截断值定义PPM,并在倾向评分匹配队列中比较有无PPM患者。

主要发现

  • 院内死亡率为0。
  • 中位随访3.8年期间,晚期房颤发生率为9.2%(24/262)。
  • POAi与术后跨瓣压差关系以指数模型拟合最佳(P<0.001)。
  • 以晚期房颤为因变量,PPM的最佳截断值为POAi≤2.28 cm²/m²(c-statistic 0.71;敏感度0.61;特异度0.80;P<0.001)。
  • PPM发生率为43.1%(113例);倾向评分匹配后,PPM组估计5年晚期房颤率显著高于非PPM组(24% vs 5%;P<0.001)。

关键数值与推荐

  • PPM定义为POAi≤2.28 cm²/m²(c-statistic 0.71;敏感度0.61;特异度0.80;P<0.001)。
  • PPM发生率为43.1%(113/262)。
  • 倾向评分匹配后PPM组5年晚期房颤率为24%,非PPM组为5%(P<0.001)。

临床怎么用

  • 在二尖瓣成形环尺寸选择时,除瓣膜尺寸外应结合患者体表面积评估PPM风险。
  • 对于体表面积较大的患者,应避免选择过小的成形环以降低术后跨瓣压差。
  • 术后应关注PPM患者的晚期房颤发生风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Elevated postoperative transmitral gradient (TMG), partially induced by a small annuloplasty ring, is associated with late atrial fibrillation (AF) after mitral valve repair. Here, we aimed to provide the optimal cut-off of prosthetic ring size to reduce patient-prosthesis mismatch (PPM) after mitral annuloplasty. METHODS: From 2006 to 2017, 262 patients who underwent mitral valve repair for degenerative pathologies were retrospectively studied. The relationships of body surface area (BSA)-indexed prosthetic orifice area (POAi)-postoperative TMG and POAi-late AF were tested using regression curves and receiver operating characteristic curves, respectively. The optimal cut-off of POAi predictive of late AF was used to define PPM. Baseline and follow-up data of patients with and without PPM were compared in propensity score-matched cohorts. RESULTS: In-hospital mortality was 0. Late AF was observed in 9.2% (24/262) patients during a median follow-up of 3.8 years. An exponential model was best fitted based on the POAi-postoperative TMG relationship (P < 0.001). Using late AF as the dependent variable, the optimal cut-off for PPM was POAi ≤2.28 cm2/m2 (c-statistic 0.71; sensitivity 0.61; specificity 0.80; P < 0.001). PPM was identified in 113 (43.1%) patients. After propensity score matching, the estimated 5-year rate of late AF was significantly higher in PPM patients than in non-PPM patients (24% vs 5%; P < 0.001). CONCLUSIONS: Postoperative TMG increases significantly with a small POAi for full ring annuloplasty. A patient's BSA should be considered in addition to valvular dimensions during the selection of a proper ring size to reduce PPM-related AF.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Ma W, Shi W, Wu W, et al. Patient-prosthesis mismatch in mitral annuloplasty for degenerative mitral regurgitation: an ignored issue. Eur J Cardiothorac Surg. 2019. PMID: 30903154. doi:10.1093/ejcts/ezz086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。