文献速递心外重症与机械循环支持

左室舒张末内径小于6.0 cm与轴流泵植入后死亡率相关

A left ventricular end-diastolic dimension less than 6.0 cm is associated with mortality after implantation of an axial-flow pump.
PubMed 文献 · J Thorac Cardiovasc Surg · 2019-01-21

OBJECTIVE: The effects of having a lower left ventricular end-diastolic dimension before HeartMate II (Thoratec Corp, Pleasanton, Calif) left ventricular assist device implantation remain unclear.…

要点

  • 术前LVEDD<6.0 cm是HeartMate II植入后总体生存率降低的独立预测因素。
  • LVEDD<6.0 cm组术后卒中发生率显著高于LVEDD≥6.0 cm组。
  • 需进一步研究其他辅助装置的安全LVEDD截断值并改进装置设计。

核心结论

  • 术前LVEDD<6.0 cm的HeartMate II受体总体生存率降低且术后卒中增加。

主要发现

  • Contal和O'Quigley方法确定LVEDD<6.0 cm(n=91)与更差生存相关。

关键数值与推荐

  • LVEDD<6.0 cm为与更差生存相关的截断值。

临床怎么用

  • 对计划植入HeartMate II的慢性心衰患者,术前应评估LVEDD,LVEDD<6.0 cm者需警惕生存劣势和卒中风险。

局限性

  • 单中心回顾性设计,结论需外部验证。
  • 未明确报告其他混杂因素调整细节及卒中定义。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The effects of having a lower left ventricular end-diastolic dimension before HeartMate II (Thoratec Corp, Pleasanton, Calif) left ventricular assist device implantation remain unclear. We analyzed our single-center data on HeartMate II implantation to determine whether having a lower left ventricular end-diastolic dimension preoperatively was associated with inferior outcomes. METHODS: From November 2003 to March 2016, 393 patients with chronic heart failure underwent primary HeartMate II implantation. We compared the preoperative left ventricular end-diastolic dimension and associated survival outcomes of these patients to determine the left ventricular end-diastolic dimension cutoff for worse overall survival. Then, we compared the preoperative demographics, stroke rate, and mortality of patients with a left ventricular end-diastolic dimension above the cutoff for worse survival with those of patients with a left ventricular end-diastolic dimension below the cutoff. RESULTS: A Cox multivariate regression model showed that low left ventricular end-diastolic dimension was an independent predictor of mortality (hazard ratio, 1.49; P = .02). The Contal and O'Quigley method showed that overall survival postimplantation was decreased in patients with a left ventricular end-diastolic dimension less than 6.0 cm (n = 91). Kaplan-Meier analysis confirmed that the left ventricular end-diastolic dimension less than 6.0 cm group had lower overall survival than the left ventricular end-diastolic dimension 6.0 cm or greater group (P = .04). Furthermore, a competing-risk analysis showed that postoperative stroke was more common in the left ventricular end-diastolic dimension less than 6.0 cm group than in the left ventricular end-diastolic dimension 6.0 cm or greater group (P < .01). CONCLUSIONS: Overall survival was decreased and postoperative stroke was increased in HeartMate II recipients with a preoperative left ventricular end-diastolic dimension less than 6.0 cm. Future research should determine the left ventricular end-diastolic dimension cutoff values for safely implanting other support devices, and device designs should be improved to better accommodate the needs of patients with a limited left ventricle size.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Kawabori M, Kurihara C, Conyer R, et al. A left ventricular end-diastolic dimension less than 6.0 cm is associated with mortality after implantation of an axial-flow pump. J Thorac Cardiovasc Surg. 2019. PMID: 30797583. doi:10.1016/j.jtcvs.2019.01.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。