吲哚菁绿近红外荧光成像与微创肺段切除术肿瘤学切缘长度增加相关
该2期前瞻性队列研究纳入53例接受机器人肺段切除术的<3 cm肺肿瘤患者,比较吲哚菁绿近红外荧光成像识别的真实段间平面与外科医生预判平面的切缘距离。31例(58.4%)实际接受吲哚菁绿成像手术,其中74.2%病例真实平面与预判平面不同,61.2%病例因成像额外获得平均2.41±1.6 cm的肿瘤至钉线切缘距离。
要点
- 吲哚菁绿近红外成像可识别与外科医生预判不同的真实段间平面。
- 多数使用病例中,成像额外增加肿瘤至钉线切缘距离。
- 整体并发症率18.5%,无死亡。
核心结论
- 在多数使用病例中,机器人肺段切除术中吲哚菁绿近红外荧光成像与肿瘤学切缘长度增加相关,且超出外科医生最佳判断。
研究设计与样本
- 2期前瞻性队列试验,纳入接受机器人肺段切除术的<3 cm肺肿瘤患者,2016年9月至2018年5月共入组53例。
- 先由2名胸外科医生共识确定预测段间平面,再通过吲哚菁绿注射标测真实平面。
- 采用7项二分类评分量表评估可行性、可重复性及额外肿瘤学切缘距离。
主要发现
- 53例中31例(58.4%)接受计划的吲哚菁绿成像手术。
- 31例中23例(74.2%)获得7/7分,表明吲哚菁绿标测的真实段间平面与外科医生预测平面不同。
- 31例中19例(61.2%)因吲哚菁绿成像使肿瘤至钉线平均额外切缘距离为2.41±1.6 cm。
- 整体并发症率18.5%(53例中10例),无死亡。
临床怎么用
- 机器人肺段切除术中可考虑使用吲哚菁绿近红外荧光成像辅助确定段间平面,以增加肿瘤学切缘距离。
局限性
- 原文未报告随机化或盲法设置。
- 仅58.4%入组患者实际接受吲哚菁绿成像手术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Near-infrared fluorescence mapping with indocyanine green dye is a recent advancement in minimally invasive segmental resection. This technique has not yet been reproduced, validated, or objectively evaluated in a large prospective case series. We hypothesized that near-infrared fluorescence mapping is associated with an increased oncological margin distance from the tumor, over and above the best judgment of the surgeon. METHODS: This was a phase 2 prospective cohort trial in patients who are undergoing robotic segmentectomy for lung tumors <3 cm. The predicted intersegmental plane was first identified by consensus between 2 thoracic surgeons. The true plane was then mapped by indocyanine green injection. A 7-item binary rating scale was used for the evaluation of feasibility, reproducibility, and added oncological margin distance from the tumor. The margin distance between the tumor and the true plane was compared with the margin distance between the tumor and the predicted plane. RESULTS: Fifty-three patients were enrolled between September 2016 and May 2018 and 31 patients (58.4%) received the planned operation with indocyanine green mapping. In 74.2% of cases (23 out of 31), a score of 7 out of 7 was achieved, indicating the true intersegmental plane identified by indocyanine green mapping was different than the predicted plane identified by the surgeon. In 61.2% (19 out of 31) of those cases, the mean additional margin distance from the tumor to the staple line attributable to the indocyanine green mapping was 2.41 ± 1.6 cm. The overall complication rate was 18.5% (10 out of 53) and there were no deaths. CONCLUSIONS: Near-infrared fluorescence mapping in robotic segmentectomy is associated with increased oncological margin length, over and above the best judgment of the surgeon, in the majority cases where it is used.
引用
- Mehta M, Patel YS, Yasufuku K, et al. Near-infrared mapping with indocyanine green is associated with an increase in oncological margin length in minimally invasive segmentectomy. J Thorac Cardiovasc Surg. 2019. PMID: 30803778. doi:10.1016/j.jtcvs.2018.12.099
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。