文献速递先天性心脏病外科

复杂法洛四联症合并MAPCAs行一期单源化至分流术后的结局

Outcomes After Initial Unifocalization to a Shunt in Complex Tetralogy of Fallot With MAPCAs.
PubMed 文献 · Ann Thorac Surg · 2019-02-14

本研究回顾了57例法洛四联症合并肺动脉闭锁及主肺动脉侧支血管(MAPCAs)患者,均行一期完全单源化至体肺动脉分流术,中位年龄6.9个月。中位随访5.4年,38例完成根治术,单源化后5年生存率为74%±6%。结论认为对MAPCAs和肺动脉最细小的患者,此策略多数可获得良好结局。

要点

  • 57例TOF/MAPCAs患者行单源化至分流术,中位年龄6.9个月。
  • 随访时肺动脉与主动脉收缩压比中位0.36,仅2例大于0.50。

核心结论

  • 对MAPCAs和肺动脉最细小的TOF/MAPCAs患者,一期单源化至分流后行心内根治术在多数病例中可获得优良结局。

主要发现

  • 57例中60%存在遗传学异常,包括22q11缺失25例和Alagille综合征8例。
  • 20例(35%)既往接受过手术(外院16例和/或本中心7例)。
  • 中位随访5.4年,9例在根治术前因肺动脉重建修订再次手术,38例完成根治术。
  • 单源化后5年生存率为74%±6%。
  • 随访时肺动脉与主动脉收缩压比中位0.36,2例大于0.50。

临床怎么用

  • 对肺动脉和MAPCAs细小、不适合同期心内根治的TOF/MAPCAs患者,可考虑一期单源化至分流术,后续再行根治术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Our approach to tetralogy of Fallot (TOF) with pulmonary atresia and major aortopulmonary collateral arteries (MAPCAs) emphasizes early single-stage unifocalization and intracardiac repair. However, a subset of patients with small native pulmonary arteries (PAs) and MAPCAs undergo unifocalization to a shunt rather than simultaneous intracardiac repair. METHODS: Patients with TOF/MAPCAs who underwent complete unifocalization to a systemic-to-PA shunt by a single surgeon were reviewed. The decision to perform simultaneous intracardiac repair was based on an intraoperative flow study or empirical assessment of PA and MAPCA size. RESULTS: From November 2001 to December 2017, 57 patients with TOF/MAPCAs underwent unifocalization to a shunt at a median age of 6.9 months. Genetic abnormalities were documented in 60% of patients, including a chromosome 22q11 deletion in 25 and Alagille syndrome in 8. Twenty patients (35%) had undergone prior surgery elsewhere (n = 16) and/or at our center (n = 7). During a median follow-up of 5.4 years, 9 patients had additional surgery to revise the PA reconstruction before complete repair, and 38 patients underwent complete repair. Five years after unifocalization, survival was 74% ± 6%. At follow-up, the median PA to aortic systolic pressure ratio was 0.36 and was greater than 0.50 in 2 patients. CONCLUSIONS: In patients with the smallest MAPCAs and PAs, single-stage unifocalization to a shunt followed by intracardiac repair yields an excellent outcome in most cases.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Bauser-Heaton H, Ma M, Wise-Faberowski L, et al. Outcomes After Initial Unifocalization to a Shunt in Complex Tetralogy of Fallot With MAPCAs. Ann Thorac Surg. 2019. PMID: 30772338. doi:10.1016/j.athoracsur.2019.01.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。