结果显示BMS组在术后早期及1年时腹主动脉真腔直径和体积变化显著更大,假腔血栓化百分比更高。

要点

  • PETTICOAT腹部BMS可有效扩大胸腹主动脉真腔。
  • BMS组术后1年内假腔血栓化百分比显著高于非BMS组。

核心结论

  • 对于慢性残余DeBakey I型主动脉夹层再干预后,PETTICOAT腹部BMS在术后第一年内有效扩大胸腹主动脉真腔并提高假腔血栓化百分比。

临床怎么用

  • 对于慢性残余DeBakey I型主动脉夹层需再干预的患者,可考虑采用PETTICOAT技术联合腹部BMS以促进主动脉重塑。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Our objective was to examine the role of the provisional extension to induce complete attachment (PETTICOAT) aortic dissection repair technique with bare metal stents (BMSs) in abdominal remodeling of residual DeBakey type I aortic dissection. METHODS: We retrospectively reviewed the records of patients with chronic aneurysm formation and residual DeBakey type I aortic dissection (ie, original acute aortic dissection DeBakey type I after primary surgical open repair) who underwent arch reoperation with frozen elephant trunk replacement or endovascular debranching with or without an abdominal BMS between December 2006 and December 2016. We analyzed diameters and volumes in 3 dimensions for the true and false lumens of the thoracic and abdominal aorta as well as the thrombosis percentage of the false lumen between the non-BMS (non-PETTICOAT) and BMS (PETTICOAT) groups. RESULTS: Forty-seven patients who had completed at least 1 year of follow-up were included. The non-BMS (without abdominal BMS) and BMS groups had significant differences in abdominal true lumen diameter and volumetric change at the first postoperative examination and at the examination 1 year after surgery (26.8 mL, median [19.4-34.1 mL, interquartile range (IQR)]) in non-BMS vs 42.5 mL, median [31.1-57.9 mL, IQR]) in BMS (postoperative survey [F test, 33.775; P = .000]) and (30.1 mL, median [20.5-34.1 mL, IQR] in non-BMS vs 46.6 mL, median [31.3-57.4 mL, IQR]) in BMS (12-month survey [F test, 14.001; P = .001]). The abdominal false lumen thrombosis percentage was higher in the BMS group than in the non-BMS group (25.6%, median [16.4%-58.9%, IQR] in non-BMS vs 54.0%, median [36.7%-65.3%, IQR] in the BMS group (F test, 6.318; P = .016). CONCLUSIONS: Following reintervention for chronic residual DeBakey type I aortic dissection, PETTICOAT abdominal dissection BMS effectively expanded the thoracic and abdominal true lumen and augmented false lumen thrombosis percentage during the first postoperative year.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Huang CY, Hsu HL, Chen PL, et al. Aortic remodeling after hybrid provisional extension to induce complete attachment aortic repair of chronic residual type I aortic dissection. J Thorac Cardiovasc Surg. 2018. PMID: 30773384. doi:10.1016/j.jtcvs.2018.12.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。