手工开窗支架保留左锁骨下动脉的TEVAR研究
本研究评估了在胸主动脉腔内修复(TEVAR)中,于主动脉支架上手工开窗以保留左锁骨下动脉(LSA)的有效性和安全性。初步结果表明该方法在多种临床情境下保留LSA血流的可行性,其技术可行性和短期结果可能支持在急诊病例中使用。
要点
- 手工开窗TEVAR保留LSA技术成功率为93.75%。
- 平均随访17.3个月,内漏4例,支架诱导新发破口2例。
- 初步结果支持该方法在急诊病例中使用的可行性。
核心结论
- 手工开窗支架保留LSA血流的TEVAR在多种主动脉病变和临床情境中可行,技术可行性和短期结果可能支持急诊使用。
主要发现
- 26例(81.25%)为zone 2着陆区单开窗保留LSA,5例(15.63%)为zone 1着陆区双开窗保留LSA和左颈总动脉,1例(3.13%)为zone 1着陆区单开窗保留LSA并烟囱技术处理左颈总动脉。
- 技术成功率(开窗与LSA成功对齐)为93.75%。
- 平均随访17.3个月,发现4例内漏和2例支架诱导的新发破口,其中3例经腔内治疗。
临床怎么用
- 对于需在zone 2或zone 1着陆的TEVAR患者,可考虑手工开窗支架保留LSA血流,尤其在急诊情况下。
局限性
- 本研究为初步结果,样本量较小(32例),随访时间较短(平均17.3个月),需进一步验证长期效果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study aimed to evaluate the efficacy and safety of a handmade fenestrated stent graft over an aortic stent graft for preserving the left subclavian artery (LSA) in thoracic endovascular aortic repair (TEVAR). METHODS: From July 2015 to October 2018, a total of 32 consecutive patients with various thoracic aortic pathologies who underwent TEVAR in which handmade fenestration over a thoracic aortic stent graft was used for LSA were included. Outcomes including technical success, procedure-related complications, perioperative mortality and morbidity and graft patency were analysed. RESULTS: Twenty-four patients (75.00%) presented with aortic dissection, 5 patients (15.63%) with thoracic aortic aneurysm and 2 patients (6.25%) with penetrating aortic ulcer; 1 patient (3.13%) required re-TEVAR due to endoleak and sac expansion from previous TEVAR for thoraco-abdominal aneurysm. TEVAR was performed in a zone 2 landing with single fenestration for LSA (26 patients, 81.25%), zone 1 landing with double fenestration for both LSA and left common carotid artery (5 patients, 15.63%) or zone 1 landing with single fenestration for LSA and a chimney graft for left common carotid artery (1 patient, 3.13%). The technical success rate, defined as the successful alignment of fenestration to LSA, was 93.75%. At a mean follow-up of 17.3 months, 4 cases of endoleak and 2 cases of stent graft-induced new entry were noted, 3 of which were treated endovascularly. CONCLUSIONS: Our preliminary results demonstrate the viability of preserving LSA blood flow in TEVAR using a handmade stent graft fenestration to treat various aortic pathologies in various clinical situations and the technical feasibility and short-term results that may justify the use of this method in emergency cases.
引用
- Kuo HS, Huang JH, Chen JS, et al. Handmade stent graft fenestration to preserve left subclavian artery in thoracic endovascular aortic repair†. Eur J Cardiothorac Surg. 2019. PMID: 30809647. doi:10.1093/ejcts/ezz049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。