杂交胸腹主动脉修复对内脏与脊髓灌注的影响:新型改良SPIDER-graft

Impact of hybrid thoracoabdominal aortic repair on visceral and spinal cord perfusion: The new and improved SPIDER-graft.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-12-15

在猪模型中比较改良SPIDER-graft杂交修复与开放修复胸腹主动脉瘤。每组7头猪(75-85 kg),改良组避免开胸和体外循环,并可将腰动脉重新植入。结果显示杂交组总主动脉阻断时间和选择性缺血时间显著更短(P < .0001),荧光微球证实腰动脉再植入组脊髓灌注最佳。

要点

  • SPIDER-graft杂交修复避免开胸和体外循环,缩短内脏缺血时间。
  • 腰动脉再植入可改善脊髓灌注,减少脊髓缺血风险。
  • 猪模型显示杂交组总主动脉阻断时间和器官选择性缺血时间显著短于开放修复。

核心结论

  • 在猪模型中,SPIDER-graft杂交修复缩短了缺血时间、避免了体外循环和开胸,并改善了脊髓灌注。

研究设计与样本

  • 猪模型研究,每组7头猪(75-85 kg),比较SPIDER-graft杂交修复(组I和组II)与开放主动脉修复(对照组)。
  • 组II将腰动脉重新植入原入路分支,评估技术可行性、缺血时间、血流及内脏和脊髓灌注。

主要发现

  • 所有组动物均实现技术成功。
  • 开放修复组总主动脉阻断时间和相关器官选择性缺血时间显著长于组I和组II(P < .0001)。
  • 荧光微球证实组II脊髓灌注最佳。

临床怎么用

  • SPIDER-graft杂交技术可能为胸腹主动脉瘤修复提供一种避免开胸和体外循环、缩短缺血时间并保护脊髓灌注的策略。

局限性

  • 研究为猪模型,样本量小(每组7头),结果需临床研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: SPIDER-graft for thoracoabdominal aortic aneurysm repair avoiding thoracotomy and extracorporeal circulation was modified, enabling reimplantation of lumbar arteries to prevent spinal cord ischemia and compared with open aortic repair (control) in a pig model. METHODS: Graft implantation was performed in 7 pigs per group (75-85 kg). For SPIDER-graft (groups I and II), the infra-diaphragmatic aorta was exposed through retroperitoneal access. The right iliac branch was first temporarily anastomosed end-to-side to the distal aorta maintaining periprocedural retrograde visceral perfusion. SPIDER-graft was deployed in the descending thoracic aorta via the celiac artery ostium. The celiac, superior mesenteric, and renal arteries were successively connected to the corresponding side branches of the graft. In group II, the lumbar arteries were reimplanted into the former access branch. For control, complete thoracoabdominal exposure of the aorta was required. After crossclamping, proximal anastomosis was performed, and the celiac artery, superior mesenteric artery, renal arteries, and iliac arteries were reattached. Technical feasibility, ischemic times, blood flow, and visceral and spinal cord perfusion in the related organs were evaluated before implantation and 3 and 6 hours after implantation using transit-time flow measurement and fluorescent microspheres. RESULTS: Technical success was achieved in all animals in all groups. Total aortic clamping time and selective ischemic times of related organs were significantly longer during open aortic repair compared with groups I and II (P < .0001). Fluorescent microspheres confirmed best spinal cord perfusion in group II. CONCLUSIONS: SPIDER-graft reduced ischemic time, avoided extracorporeal circulation and thoracotomy, and improved spinal cord perfusion during thoracoabdominal aortic aneurysm repair in a pig model.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。