缺血性/功能性二尖瓣反流瓣环成形环对急性缺血羊心左心室尺寸的影响
在30只羊急性缺血模型中,植入三种针对缺血性/功能性二尖瓣反流的瓣环成形环(PHY、ETL、GEO)后,所有环均显著缩小二尖瓣环的室间隔-侧壁(S-L)和交界-交界(C-C)尺寸,但除GEO轻微减小左心室基底段S-L尺寸外,左心室整体S-L和C-C尺寸均无显著改变。结论认为,尽管瓣环尺寸大幅减小,疾病特异性瓣环成形环并不引起左心室尺寸的明显变化。
要点
- 三种瓣环成形环均显著缩小二尖瓣环S-L和C-C尺寸。
- 左心室S-L和C-C尺寸在植入环后基本保持不变。
- GEO环仅轻微减小左心室基底段S-L尺寸(-2.3±2.4%)。
核心结论
- 疾病特异性缺血性/功能性二尖瓣反流瓣环成形环虽大幅缩小二尖瓣环,但在急性缺血羊心中不引起左心室尺寸的明显改变。
研究设计与样本
- 在30只羊的左心室二尖瓣环及基底、赤道、心尖水平放置不透射线标记,分别植入10枚真尺寸的PHY、ETL和GEO瓣环成形环,于左回旋支闭塞90秒后采集四维标记坐标,比较植入环与释放环后的数据。
主要发现
- 与无环相比,PHY、ETL和GEO分别使二尖瓣环S-L尺寸减小-20.7±5.6%、-26.8±3.9%和-34.5±3.8%。
- GEO仅使左心室基底段S-L尺寸减小-2.3±2.4%,其余左心室S-L尺寸在所有环植入后均无变化。
- PHY、ETL和GEO分别使二尖瓣环C-C尺寸减小-17.5±4.8%、-19.6±2.5%和-8.3±4.9%,但所有环均未改变左心室C-C尺寸。
关键数值与推荐
- 二尖瓣环S-L尺寸变化:PHY -20.7±5.6%,ETL -26.8±3.9%,GEO -34.5±3.8%。
- 二尖瓣环C-C尺寸变化:PHY -17.5±4.8%,ETL -19.6±2.5%,GEO -8.3±4.9%。
- 左心室基底段S-L尺寸变化:GEO -2.3±2.4%,其余环及左心室其他S-L尺寸无变化。
临床怎么用
- 在心胸外科临床中,选用针对缺血性/功能性二尖瓣反流的瓣环成形环时,应了解其主要作用于二尖瓣环而非左心室尺寸。
局限性
- 研究为急性缺血羊心模型,结果不能直接推断至慢性缺血或人类。
- 样本量有限(每组10只),长期效果未评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To quantify the effects of annuloplasty rings designed to treat ischemic/functional mitral regurgitation on left ventricular septal-lateral (S-L) and commissure-commissure (C-C) dimensions. METHODS: Radiopaque markers were placed as opposing pairs on the S-L and C-C aspects of the mitral annulus and the basal, equatorial, and apical level of the left ventricle (LV) in 30 sheep. Ten true-sized Carpentier-Edwards Physio (PHY), Edwards IMR ETlogix (ETL), and GeoForm (GEO; all from Edwards Lifesciences, Irvine, Calif) annuloplasty rings were inserted in a releasable fashion. After 90 seconds of left circumflex artery occlusion with the ring implanted (RING), 4-dimensional marker coordinates were obtained using biplane videofluoroscopy. After ring release, another data set was acquired after another 90 seconds of left circumflex artery occlusion (NO RING). S-L and C-C diameters were computed as the distances between the respective marker pairs at end-diastole. Percent change in diameters was calculated between RING versus NO RING as 100 × (diameter in centimeters [RING] - diameter in centimeters [NO RING])/diameter in centimeters [NO RING]). RESULTS: Compared with NO RING, all ring types (PHY, ETL, and GEO) reduced mitral annular S-L dimensions by -20.7 ± 5.6%, -26.8 ± 3.9%, and -34.5 ± 3.8%, respectively. GEO reduced the S-L dimensions of the LV at the basal level only by -2.3 ± 2.4%, whereas all other S-L dimensions of the LV remained unchanged with all 3 rings implanted. PHY, ETL, and GEO reduced mitral annular C-C dimensions by -17.5 ± 4.8%, -19.6 ± 2.5, and -8.3 ± 4.9%, respectively, but none of the rings altered the C-C dimensions of the LV. CONCLUSIONS: Despite radical reduction of mitral annular size, disease-specific ischemic/functional mitral regurgitation annuloplasty rings do not induce relevant changes of left ventricular dimensions in the acutely ischemic ovine heart.
引用
- Bothe W, Kvitting JP, Rausch MK, et al. Do annuloplasty rings designed to treat ischemic/functional mitral regurgitation alter left-ventricular dimensions in the acutely ischemic ovine heart? J Thorac Cardiovasc Surg. 2019. PMID: 30803776. doi:10.1016/j.jtcvs.2018.12.077
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。